13
STT-869 – wireless
thermostatic actuator
- Opening/closing the valve in
order to maintain desired
temperature value
The actuator should be
registered in the external
controller
C-2 – window sensor
- It sends information to the
main controller when the
window is opened/closed.
The sensor should be installed
in the window of a given zone
and it should registered to a
the zone.
C-8f – floor sensor
- It sends information about
current floor temperature.
The sensor should be
registered in a given zone.
MW-1 – executive module
- It enables wireless activation of
a given output in the external
controller. Depending on
selected operation mode, MW-1
may be used to activate CH
boiler operation, the pump or
valve actuators.
The module should be