Description

EU-R-8b  room  regulator  is  intended  for  cooperation  with  L-8  external 

controller. 

 

EU-R-8b room regulators are installed in the heating zones. 

Temperature  information  sent  by  them  to  the  external  controller  is 

used  to  control  the  thermostatic  valves  (by  opening  them  when  the 

room temperature is too low and closing them when the pre-set room 

temperature has been reached). 

 

Current  temperature  is  displayed  in  the  main  screen.  The 

user  may  also  change  the  pre-set  temperature  permanently  or  for  a 

limited period of time directly from the sensor. 

 

Controller equipment:

• 

built-in temperature sensor

• 

wall-mountable cover

Battery low

In case of low battery, the „Lo” message will appear on the screen. To 

ensure  correct  operation  of  the  regulator  please  change  the  batteries 

(2xAAA 1,5V)

 How to use the controller

1. Display – current zone temperature.
2. MINUS button
3. PLUS button 
4. Icon 

• 

flashing - 

the set temperature has not been reached

• 

highlighted - 

the set temperature has been reached

How to register the room regulator in a 

particular zone

Each room regulator should be registered in a zone. In order to register, 

go to the L-8 menu and select Sensor in the submenu of a given zone 

(Zone/Registration/Sensor). After selecting the Register icon, press the 

communication button on the back of the room regulator.  

 

If the registration process has been completed successfully, 

L-8  screen  displays  an  appropriate  message  whereas  the  room  sensor 

screen  displays  “Scs”.  If  the  room  sensor  displays  “Err”,  an  error  has 

occurred during the registration process. 

NOTE

Only one room regulator may be assigned to each zone. 

The following rules must be kept in mind:

- once registered, the regulator cannot be unregistered, but only switched 

off in the submenu of a given zone,

- if the user attempts to assign a sensor to the zone to which other sensor 

has already been assigned, the first sensor becomes unregistered and it 

is replaced by the second one. 

- if the user attempts to assign a sensor which has already been assigned 

to a different zone, the sensor is unregistered from the first zone and 

registered in the new one.

It  is  possible  to  set  individual  pre-set  temperature  value  and  weekly 

schedule for each room regulator assigned to a given zone. The settings 

may be configured both in the main menu of L-8 external controller (Main 

menu/Sensors) and via www.emodul.eu (using EU-505 or WiFi RS). The 

pre-set temperature may also be adjusted directly from the room sensor 

using PLUS and MINUS button.

How to change the pre-set temperature

The  pre-set  zone  temperature  may  be  adjusted  directly  from  EU-R-8b 

room sensor using PLUS and MINUS buttons.

 

During controller inactivity, the main screen displays current 

zone temperature. After pressing PLUS or MINUS, the current temperature 

is replaced with the pre-set temperature (the digits are flashing). Using 

PLUS  and  MINUS  the  user  may  adjust  the  pre-set  temperature  value. 

After setting desired value wait for 3 seconds – after this time the display 

shows a panel to define how long the new setting should apply. 

 

Time settings may be adjusted:  

-  permanently  –  press  PLUS  button  until  Con  appears  on  the  screen  ( 

the pre-set value will apply all the time regardless of schedule settings), 

- for a specified number of hours – press PLUS or MINUS until the desired 

number of hours appears on the screen e.g. 01h (the pre-set value will 

apply for a specified period of time; after that the weekly schedule will 

apply). 

- if the temperature value defined in the weekly schedule settings should 

apply, press MINUS until the screen displays OFF.

Description of the functions available in the 

menu

In order to enter the menu, press and hold PLUS and MINUS buttons. Use 

PLUS and MINUS buttons to navigate among menu functions. 

1.Bat  -  this  function  enables  the  user  to  check  the  battery  level  (%). 

After Bat function has been selected, the screen flashes for 3 seconds and 

displays the battery level. 

2.Cal - This function enables the user to view sensor calibration. After Cal 

function has been selected, the screen flashes for 3 seconds and displays 

the calibration value.  

3.Loc - This function enables the user to activate button lock. After Loc 

function  has  been  selected,  the  screen  flashes  for  3  seconds  and  you 

are asked if you want to activate the lock (yes/no). Confirm using PLUS 

or MINUS button. In order to confirm your choice, wait 3 seconds. Once 

the lock has been activated, the buttons are locked automatically after 

10  seconds  of  inactivity.  In  order  to  unlock,  press  and  hold  PLUS  and 

MINUS at the same time. When Ulc appears on the screen, the buttons 

have been unlocked.  

4.Def - This function enables the user to restore factory settings. Once 

Def function has been selected, the screen flashes for 3 seconds and you 

are asked if you want to restore factory settings (yes/no). Select using 

PLUS or MINUS. Wait 3 seconds to confirm your choice. 

5.Ret - exit the menu. Once Ret has been selected, the screen flashes for 

3 seconds and returns from the menu to the main screen view.  

EU Declaration of conformity

 

Hereby,  we  declare  under  our  sole  responsibility  that 

EU-R-8b

  

manufactured  by  TECH  STEROWNIKI,  head-quartered  in  Wieprz  Biała 

Droga  31,  34-122  Wieprz,  is  compliant  with  Directive  2014/53/EU  of 

the  European  parliament  and  of  the  Council  of  16  April  2014  on  the 

harmonisation of the laws of the Member States relating to the making 

available  on  the  market  of  radio  equipment,  Directive  2009/125/EC 

establishing a framework for the setting of ecodesign requirements for 

energy-related products as well as the regulation by the MINISTRY OF 

ENTREPRENEURSHIP AND TECHNOLOGY of 24 June 2019 amending the 

regulation concerning the essential requirements as regards the restriction 

of  the  use  of  certain  hazardous  substances  in  electrical  and  electronic 

equipment, implementing provisions of Directive (EU) 2017/2102 of the 

European Parliament and of the Council of 15 November 2017 amending 

Directive 2011/65/EU on the restriction of the use of certain hazardous 

substances in electrical and electronic equipment (OJ L 305, 21.11.2017, 

p. 8).
For compliance assessment, harmonized standards were used:

PN-EN IEC 60730-2-9 :2019-06 par.3.1a Safety of use

ETSI  EN  301  489-1  V2.1.1  (2017-02)  par.3.1  b  Electromagnetic 

compatibility

ETSI  EN  301  489-3  V2.1.1  (2017-03)  par.3.1  b  Electromagnetic 

compatibility

ETSI EN 300 220-2 V3.1.1 (2017-02) par.3.2 Effective and coherent use 

of radio spectrum

ETSI EN 300 220-1 V3.1.1 (2017-02) par.3.2 Effective and coherent use 

of radio spectrum

Wieprz, 11.02.2021

Technical data

Range of room temperature settings........................................5-350C

Power supply .....................................................batteries 2xAAA 1,5

Accuracy of measurement....................................................+/-0,50C

Frequency...........................................................................868MHz

 We  are  committed  to  protecting  the 

environment. 

Manufacturing 

electronic 

devices  imposes  an  obligation  of  providing 

for  environmentally  safe  disposal  of  used 

electronic  components  and  devices.  Hence, 

we have been entered into a register kept by 

the  Inspection  For  Environmental  Protection. 

The  crossed-out  bin  symbol  on  a  product 

means  that  the  product  may  not  be  disposed 

of to household waste containers. Recycling of 

wastes helps to protect the environment. The 

user is obliged to transfer their used equipment 

to  a  collection  point  where  all  electric  and 

electronic components will be recycled.