TECH
11
7.
NIGHT FROM…
The Night from... function defines the exact time when the nighttime
starts. In order to set this parameter, press MENU button until the
nighttime setting screen appears. Use PLUS and MINUS to set the hour
and minute of night mode activation. Confirm by pressing MENU button
(confirm and move on to edit the next parameter) or EXIT button
(confirm and return to the main screen view). Changes will also be saved
automatically after 5 seconds of inactivity.
8.
SENSOR HYSTERESIS
Room temperature hysteresis defines the pre-set temperature tolerance in order to prevent undesired oscillation in case
of small temperature fluctuation (within the range of 0,2 ÷ 5°C).
Example:
Pre-set temperature: 23°C
Hysteresis: 1°C
The room regulator reports that the temperature is too low when the
room temperature drops to 22 °C.
In order to set the hysteresis, press MENU until the hysteresis settings appear on the screen.
Use PLUS and MINUS to set the desired hysteresis value. Press MENU to confirm and move on to the next parameter or
press EXIT to confirm and return to the main screen view. Changes will also be saved automatically after 5 seconds of
inactivity.
9.
FLOOR SENSOR
In order to enable or disable the floor heating, press the MENU button
until the floor heating screen appears.
In order to enable the floor heating, press PLUS button ( ON will be
displayed on the screen).
In order to disable the floor heating, press MINUS button ( OFF will be
displayed on the screen). To confirm, press MENU button (confirm
and go on to edit the next parameter) of EXIT button (confirm and
return to the main screen view). Changes will also be saved
automatically after 5 seconds of inactivity.
NOTE
Correct operation of a regulator with a floor sensor is possible
only in the mode
RS REGULATOR
→
STANDARD
REGULATOR
.
When the floor sensor is enabled, make sure that the minimum
valve opening in the controller (EU-I-2, EU-I-2 Plus, EU-I-3, EU-
I-3Plus) is set at the minimum of 5% or more.