UNDERFLOOR HEATING H YSTERESIS
Underfloor heating hysteresis defines the tolerance for the maximum and minimum temperature. The settings range is
0,2°C to 5 °C.
If the floor temperature exceeds the maximum temperature, the underfloor heating will be disabled. It will be enabled
only after the temperature has dropped below the maximum floor temperature minus hysteresis value.
Example:
Maximum floor temperature: 33°C
Hysteresis: 2°C
When the floor temperature reaches 33°C, the underfloor heating will
be disabled. It will be activated again when the temperature drops to
31°C.
If the floor temperature drops below the minimum temperature, the underfloor heating will be enabled. It will be disabled
after the floor temperature has reached the minimum value plus hysteresis value.
Example:
Minimum floor temperature: 23°C
Hysteresis: 2°C
When the floor temperature drops to 23°C, the underfloor heating will be enabled. It will be disabled when the
temperature reaches 25°C.
11.
MAXIMUM FLOOR TEMPERATURE
In order to set the maximum floor temperature, activate the underfloor
heating and press MENU until the maximum floor temperature settings
appear on the screen. Use PLUS and MINUS to set the temperature.
Confirm by pressing MENU button (confirm and move on to edit the next
parameter) or EXIT button (confirm and return to the main screen view).
Changes will also be saved automatically after 5 seconds of inactivity.
12.
MINIMUM FLOOR TEMPERATURE
In order to set the minimum floor temperature, activate the underfloor
heating and press MENU until the minimum floor temperature settings
appear on the screen. Use PLUS and MINUS to set the temperature.
Confirm by pressing MENU button (confirm and move on to edit the
next parameter) or EXIT button (confirm and return to the main screen
view). Changes will also be saved automatically after 5 seconds of
inactivity.