TECH
No. Specification
Unit
1
Power Supply
V
230V/50Hz +/-10%
2
Power Consumption
W
4
3
Ambient Temperature
°C
1.10.1950
4
Feeder Output Load
A
2,5
5
Circulation Pump Output Load
A
1
6
Fan Output Load
A
1
7
Temperature Measurement Range
°C
0-85
8
Measurement Accuracy
°C
1
9
Temperature Adjustment Range
°C
40-80
10
Sensor Thermal Resistance
°C
-25;90
11
Fuse Insert
A
6,3
We are committed to protecting the environment. Manufacturing electronic devices imposes
an obligation of providing for environmentally safe disposal of used electronic components
and devices.
Hence, we have been entered into a register kept by the Inspection For
Environmental Protection. The crossed-out bin symbol on a product means that the product
may not be disposed of to household waste containers
.
Recycling of wastes helps to protect
the environment. The user is obliged to transfer their used equipment to a collection point
where all electric and electronic components will be recycled.
V. Assembly
ATTENTION: all assembly works must only be carried out by qualified
persons.
During assembly, the device
must be
disconnected (make sure the
power cord is unplugged)!
ATTENTION:
improper cable connection may damage the regulator!
ATTENTION:
the
ST-37
controller must be built into the boiler so that the
cable connection strips are not accessible.
The regulator may not be operated in a closed-circuit central heating system.
It is necessary to provide for safety valves, pressure valves and a surge tank
in order to prevent water from boiling in the central heating system.