TECH
temperature
. This is a difference between the temperature of entering
into the
sustain
cycle and the temperature of returning to the
duty
cycle
(e.g.: when the
setpoint temperature
is set to 60°C, and the hysteresis is
set to 3°C, entering into the
sustain
cycle will be effected after the
temperature reaches 60°C, whereas return to the
duty
cycle will be
effected after the temperature drops to 57°C).
III.6.H.C.W. Hysteresis
With this function, you can set the hysteresis of the setpoint temperature
on the water heater.
This is a difference between the setpoint temperature (required by the
water heater) and the actual temperature on the water heater (e.g.:
when the setpoint temperature is set to 55
o
C and the hysteresis is set to
5
o
C). After reaching the setpoint temperature, i.e. 55°C, the hot
consumption water pump is shut off, causing the central heating pump to
be activated. The hot consumption water pump will be activated again
when the temperature drops to 50°C.
III.7.Floor Heating Pump
With this function, you can control the floor heating. You can set the floor
-17-
FITTER’S MENU
Exit
H.C.W. Hysteresis
Floor Pump
Circulation Pump
FITTER’S MENU
Exit
H.C.W. Hysteresis
Floor Pump
Circulation Pump
FLOOR PUMP
Exit
On
Off
Min Temperature