heating temperature in a range between 20°C and 55°C. You can also set
the pump switch-on and shut-off threshold, e.g. 25°C, meaning that
when the temperature drops below this value, the pump is shut off, and
when it rises above this value, the pump runs until the setpoint
temperature is reached. When the setpoint temperature has been
reached, e.g. 45°C, the floor heating pump is shut off. The floor heating
pump will be re-activated when the temperature drops to 2°C).
III.8.Circulation Pump
With this function, you can control the pump that is responsible for
mixing hot water between the boiler and hot consumption water
receivers. Operation and pause times are set by the user.
III.9.Automatic Mode of Feeder
With this function, you can disable or enable the automatic feed (e.g. in
order to damp the boiler).
-18-
FITTER’S MENU
Exit
H.C.W. Hysteresis
Floor Pump
Circulation Pump
CIRCULATION PUMP
Exit
On
Off
Operation Time
FITTER’S MENU
Exit
Feeder in Auto Mode
Language Version
Software Version