ST-45 User's Manual
Press the
ENCODER
to enable / disable the blow.
Press the
ENCODER
to enable / disable the central heating pump.
Press the
ENCODER
to enable / disable the (water heater) hot
consumption water pump.
Press the
ENCODER
to enable / disable the floor heating pump.
Press the
ENCODER
to enable / disable the mixing pump.
Press the
ENCODER
to enable / disable the alarm.
II.6.Feed Time
With this function, you can set the operation time for the fuel feeder. Set
the operation time according to the type of fuel and boiler used.
II.7.Feed Interval
With this function, you can set the stand-by time for the feeder,
depending on the type of fuel used in the boiler. Incorrect operation and
stand-by times may cause the boiler to malfunction, i.e. inability to burn
all carbon and to reach the setpoint temperature. Setting correct times
will ensure correct boiler operation.
II.8.Blow Force
With this function, you can control the fan speed. The adjustment range
is from 10 to 100% (it can be assumed that the fan operates in gears).
-8-
MENU
Exit
Manual Mode
Feed Time
Feed Pause
MENU
Exit
Blow Force
Operation Mode
Sustain Mode