ST-707 Rotations Control
II.7. Manual mode
For the user's convenience, the regulator has been equipped with a
Manual operation
module. In this function, each executive device (the
feeder, the blow-in, the CH pump, the HUW pump, the circulation pump
and the floor pump) is activated and deactivated independently of the
others.
Pressing the
pulse generator
activates the engine of the chosen
device. This device remains activated until the
pulse generator
is
pressed again.
The
blow-in power
, where the user has the possibility to set any
rotational speed of the fan in manual operation, is additionally available.
II.8. Operation mode
In this function, the user selects one of four options of the boiler's
operation.
II.8.a) House heating
By choosing this option, the regulator switches to heating the house
only. The CH pump starts to work above the pump activation threshold
(preset to 40
O
C). Below this temperature the pump stops working.
- 10 -