ST-707 Rotations Control
expectation, is should be
registered
by entering the module number
(this is number of the valve in accordance with the documentation) and
then several parameters should be set.
1.
Switch on
This feature allows you to temporarily make the valve inactive.
2. Temperature control
In this function, the opening time of the valve is set - in other
words, how long it takes the valve to open to the value of 100%. This
time should be selected in accordance with the owned valve servomotor
(stated on the rating plate).
3. Opening time
In this function, the time of full valve opening is set, in other words,
how long it takes the valve to open to the value of 100%. This time
should be selected according to the owned valve servomotor (stated on
the rating plate).
4. Unit step
In this function, the unit percentage valve opening stroke, that is the
minimum percent of opening or closing the valve is expected to execute,
is set.
- 15 -