ST-707 Rotations Control

thermoregulator operation screens. They are:

CH screen (the current boiler operation mode is displayed),

valve 1 (displays the operational parameters of the first valve),

valve 2 (displays the operational parameters of the second valve).

manufacturer's screen - this view is unavailable to the user. This is 
a special screen view only for the device's manufacturer.

NOTE

To make the views with valve parameters active, these valves must be 
earlier accordingly installed and configured by the installer.

II.4. Ignition

The   boiler   can   be   easily   kindled   using   this   function.   After   initial 

lighting   up   of   a   fire   source,   the   user   activates   the   automatic   ignition 
cycle.   Thanks   to   selection   of   optimum   parameters,   the   boiler   will 
smoothly switch to the operation mode using the PID function.

II.5. Set CH

This option is used to adjust the set boiler temperature. The user may 

change the temperature range in the boiler from 45

O

 C to 80

O

 C. The set 

CH   can   also   be   changed   directly   from   the   main   controller   screen   by 
turning the pulse generator knob.

II.6. Set HUW

This option is used to adjust the set value of the hot utility water 

temperature. The user may change this temperature in the range from 
40

O

 C to 75

O

 C.

- 9 -

Summary of Contents for ST-707

Page 1: ......

Page 2: ...A 34 122 Wieprz is compliant with the Regulation by the Ministry of Economy Journal of Laws Dz U 155 Item 1089 of July 21 2007 implementing provisions of the Low Voltage Directive LVD 2006 95 EC of Ja...

Page 3: ...sconnected from the mains before working on the power supply cable connections device installation etc All connection works must only be carried out by qualified electricians Before activating the con...

Page 4: ......

Page 5: ...e GSM module and the Ethernet module The advantage of this controller is its simplicity in operation The User makes all changes of parameters by means of the pulse generator knob Another advantage is...

Page 6: ...ID regulator Each controller should be set individually for own needs depending on the type of fuel used for burning as well as the type of the boiler The TECH company will not be liable for any incor...

Page 7: ...wn needs After activation of the controller the name of the manufacturer of the boiler as well as the version of the program are displayed on the graphic display A message with language selection appe...

Page 8: ...30 seconds preset extinguishment time the regulator switches to the extinguishment condition In this state the blow in and the feeder stop working and the following message is shown on the display PID...

Page 9: ...staller II 4 Ignition The boiler can be easily kindled using this function After initial lighting up of a fire source the user activates the automatic ignition cycle Thanks to selection of optimum par...

Page 10: ...ngine of the chosen device This device remains activated until the pulse generator is pressed again The blow in power where the user has the possibility to set any rotational speed of the fan in manua...

Page 11: ...the CH pump and the HUW pump The valve mounted on the HUW pump prevents hot water from being sucked out of the reboiler II 8 c Parallel pumps In this mode both pumps work simultaneously above the pum...

Page 12: ...Select specific hours and required deviations from the preset temperature how many degrees the temperature should rise or drop for each day of the week Additionally the preset values can be copied to...

Page 13: ...main page of the controller next to the preset central heating system temperature This additionally indicates that the weekly control is active Data deletion function is a simple method to remove all...

Page 14: ...t temperature of the boiler and the mixing valves An additional advantage of the device is the weekly heating program and the parental lock protecting against unwanted changes in the settings After ac...

Page 15: ...ds how long it takes the valve to open to the value of 100 This time should be selected in accordance with the owned valve servomotor stated on the rating plate 3 Opening time In this function the tim...

Page 16: ...a sensor should have the function of Weather sensor activated in a controller menu To make sure that the valve works correctly the set temperature is set behind the valve for three intermediate exter...

Page 17: ...t for external temperatures XA XB XC O1 operation of increasing the set Temperatura zewn trzna External temperature Temperatura zadana Set temperature Increasing reduction the set temperature consists...

Page 18: ...r 10 Pump activation temperature This option is used to set CH and HUW pump activation temperature this is the temperature measured on the boiler Both pumps do not operate below the set temperature an...

Page 19: ...d feature The GSM module is an optional device cooperating with the boiler controller enabling remote control of the boiler operation with the use of a mobile phone The User is notified with a text me...

Page 20: ...changes of the set temperatures for both the pumps and the mixing valves After activating the Internet module and selecting the DHCP option the controller will automatically download such parameters f...

Page 21: ...operation of the feeder The feeder can be switched off for manual fuel feeding or to cause the boiler to be extinguished II 12 j Fan auto mode Automatic operation of the fan can be enabled or disable...

Page 22: ...emperature alarm is activated is set with this function If the boiler temperature does not rise to the set temperature during the set time the alarm will be activated After pressing the knob of the pu...

Page 23: ...PID operation will simultaneously disappear from the main menu and the installer s menu after selection of operation of the controller without PID ignition extinguishing boiler power air adjustment fu...

Page 24: ...play The alarm will be disabled after pressing the pulse generator knob The regulator then returns to the recently set operation mode III 2 Thermal protection It is an additional bimetallic mini senso...

Page 25: ...ation mode until the temperature of 62O C is reached III 5 Temperature protection The regulator is equipped with additional protection in the event of damage to the bimetallic sensor After exceeding t...

Page 26: ...stening of the controller clean it from dust and other dirt Earthing effectiveness of the engines of the CH pump HUW pump the blow in the feeder the floor pump and the circulation pump should also be...

Page 27: ...dard equipment of controller ST 707 Rotations Control cable feeding CH pump ended with a plug L 2 5m 1pc able feeding HTW pump ended with a plug L 2 5m 1pc cable feeding the mixing pump ended with a p...

Page 28: ......

Page 29: ...II 10 Fuel granulation 13 II 11 Installer s menu 13 II 12 c Room regulator 14 II 12 d Valve 1 and 2 14 1 Switch on 15 2 Temperature control 15 3 Opening time 15 4 Unit step 15 5 Minimum opening 16 6 V...

Page 30: ...Automatic sensor control 24 III 4 Anti boiling protection for the water in the boiler 25 III 5 Temperature protection 25 III 6 Protection of fuel container 25 III 7 Fuel container protection 25 III 8...

Page 31: ...vices Hence we have been entered into a register kept by the Inspection For Environmental Protection The crossed out bin symbol on a product means that the product may not be disposed of to household...

Page 32: ...ST 707 Rotations Control 32...

Reviews: