This function allows to set up the temperature of turning CH and
CHW Pumps on (it’s the temperature measured in the boiler). Below the
set temperature both pumps don’t work, above the set temperature both
pumps are turned on, but they work depending on the settings, i.e. they
are turned on alternately (see function priority pump or constant CH
pump)
II.f) CHW Hysteresis
This function allows for setting up the hysteresis of the set
temperature in the boiler. It is a difference between the set temperature
(so the temperature the user wants to have in the boiler) and the
temperature that is in the boiler at a certain time (e.g. if the set
temperature equals 55 C and hysteresis equals 5 C: after reaching the
set temperature, i.e. 55 C, the CHW pump turns itself off and the CH
pump turns itself on; the CHW pump will turn itself on again after the
temperature drops to 50 C).
II.g) Hysteresis
- 8 -
Feeder BreakTime
CH and CHW Pump
35
o
c
CH and CHW Pump
62
o
c 72
o
c
CH Set Temp
62
o
c 72
o
c
CH . Set Temp
CH and CHW Pump
CHW Hysteresis
10
o
c
CHW Hysteresis