ST- 85 – USER'S MANUAL

pump mode. To be able to operate the boiler in all modes, it is necessary to 

replace the sensor.

III.c) Temperature Protection

The regulator features an additional protection in case the bimetal sensor 

is damaged. After the temperature exceeds 85

O

C, the alarm is sounded with 

the display showing the following message:

The current temperature is read from an electronic sensor                     and 

processed by the thermoregulator. When the alarm temperature is exceeded, 

the fan is shut off and both pumps begin to run in order to distribute hot 

consumption water throughout the system.

III.d) 

Anti-Boil Protection

This   protective   function   is   used   only   with   the  

water   heater   priority 

mode. For example, when the water heater setpoint temperature is 55

O

C and 

the   boiler   temperature   rises   to   67

O

C  (5

O

C   over   the  so-called  

priority 

temperature

),   the   controller   shuts   off   the   fan.If   the   boiler   temperature 

reaches 80

O

C, the C.H. pump will be activated. If the temperature continues 

to rise, the alarm will be activated at 85

O

C. Such condition may appear when 

the   water   heater   or   the   pump   is   damaged   or   when   the   sensor   has   been 

improperly installed. However, if the temperature drops, the controller will 

activate the fan at 66

O

C and it will remain in the duty mode maintaining the 

priority temperature of 62

O

C. 

- 17 -

Alarm

Temperature Too 

High

Summary of Contents for ST-85

Page 1: ......

Page 2: ...mpliant with the Regulation by the Ministry of Economy Journal of Laws Dz U 155 Item 1089 of July 21 2007 implementing provisions of the Low Voltage Directive LVD 2006 95 EC of January 16 2007 The ST...

Page 3: ...from the mains before working on the power supply cable connections device installation etc All connection works must only be carried out by qualified electricians Before activating the controller mea...

Page 4: ...Blow...

Page 5: ...and its power depends directly on the measured boiler temperature and flue gas temperature as well as the difference between the two parameters and their setpoint values Advantages of zPID regulators...

Page 6: ...sults presented below were obtained using the Tech PID based controller and the controller without PID control You can change all parameters with an encoder knob Turning the knob allows you to select...

Page 7: ...The duty cycle is the basic functionality of the regulator The blow is controlled automatically using the zPID algorithm and the temperature is close to its setpoint value In the user menu fan item wi...

Page 8: ...user II a Main Page During normal operation the LCD display shows the Main Page containing the following Boiler temperature to the left of the display Setpoint temperature to the right of the display...

Page 9: ...to easily fire up the boiler After igniting the boiler you need to activate an automatic fire up cycle By selecting optimum parameters the boiler uses the zPID function to smoothly switch to the duty...

Page 10: ...ction allows you to set the blow force of the fan while in the Manual Mode Pressing the ENCODER activates the fan The fan will operate until the ENCODER is pressed again Press the ENCODER to enable di...

Page 11: ...this case the pump will stop at boiler temperature of 33O C II g H C W Pump Activation With this function you can set the temperature that will activate the hot consumption water pump the temperature...

Page 12: ...o switch into the water heater priority mode In this mode the hot consumption water heater pump is activated until the set H C W temperature is reached Then the H C W pump is shut off and the C H pump...

Page 13: ...esholds are exceeded the pumps will operate simultaneously The central heating pump runs continuously while the hot consumption water pump stops after the setpoint temperature is reached in the water...

Page 14: ...heater While in the Summer Mode the icon is displayed in the up right corner of the main screen II i Main Screen This function allows you to change the view of the main screen The following views are...

Page 15: ...re configured However it should be adjusted to your individual needs It is possible to return to the factory settings at any time By enabling the Factory Settings all existing boiler settings will be...

Page 16: ...em when the boiler has been overheated or the controller is damaged When the protective function is enabled and the temperature drops to a safe value the sensor will automatically restart the device a...

Page 17: ...hroughout the system III d Anti Boil Protection This protective function is used only with the water heater priority mode For example when the water heater setpoint temperature is 55O C and the boiler...

Page 18: ...is operated using only the boiler sensor and the zPID function remains active without the flue gas outlet sensor III f Fuse The regulator has a network protection WT 3 15 A tube fuse Higher current r...

Page 19: ...orks must only be carried out by qualified persons During assembly the device must be disconnected make sure the power cord is unplugged ATTENTION improper cable connections may damage the regulator T...

Page 20: ...ST 85 USER S MANUAL 20...

Page 21: ...ces Hence we have been entered into a register kept by the Inspection For Environmental Protection The crossed out bin symbol on a product means that the product may not be disposed of to household wa...

Page 22: ...on 11 II h Operation Mode 12 II h 1 House Heating 12 II h 2 H C W Priority 12 II h 3 Parallel Pumps 13 II h 4 Summer Mode 13 II i Main Screen 14 II j Language 15 II k Factory Settings 15 II l Fitting...

Page 23: ...ST 85 USER S MANUAL 23...

Page 24: ...ST 85 USER S MANUAL 24...

Reviews: