TS8200D Series
Micro-Meter Mix Quick Start Guide
e.
Make sure that the high-pressure seals sit and fit properly along the groove
located inside the manifold.
f.
Align the manifold with the now-assembled pump and pump housing. The
engraved labels “RESIN” and “HARDENER” should be facing you
. Insert and
fasten four 3.0 mm hex screws with lock washers in the order shown in the image
below. Make sure the two now-assembled pumps are vertically symmetrical and
not flaring outwards. Make sure there are no gaps or any visible
light between pump housing and mating parts. If there are issues,
relieve tension on the screws and tighten evenly.
g.
Install fluid inlet fittings. There are several different fluid inlet fittings available.
The fluid inlet fitting required will depend on the fluid reservoir option you select.
In the picture below, we use 1/8
”
NPT x luer lock elbow. Reference the
“Accessories” section for information
on fluid inlet fittings. It is recommended that
Teflon tape be applied to the thread of the fluid inlet fitting prior to installation.