Pin
Signal
1
F_24V
2
EXO1_00
3
EXO1_01
4
EXO1_02
5
PE
Figure 69: SYSLIGHT Connection
Be noted that this connection must be under NPN sink-input type for DIO.
Users should complete the SYSLIGHT connection by themselves.
Connect Power Supply to TM Palletizing Operator
1.
Before establishing the AC power connections, refer to the table below regarding the AC input
specifications of the TM Palletizing Operator.
Parameter
Min.
Typical
Max.
Unit
Input voltage
100
-
240
VAC
External AC fuse (100V – 120V)
-
-
16
A
External AC fuse (220V – 240V)
-
-
11
A
Input frequency
43
-
63
Hz
Table 20: AC Input Specifications of TM Palletizing Operator