TM Palletizing Operator User’s Manual
Product Version: 1.1 Document Version: 1.2
145
Figure 109: Bool Value for True
Note
:
If the
bool
value is
true
, the pillar will perform automatic calibration. If the
bool
value is
false
, the pillar will use the user input values in other variable settings as the voltage values
as the maximum and the minimum.
4.
Calibration test. Press
PLAY
/
PAUSE
button on the teach pendant to start the test. If
successful, the screen will prompt a
Calibration OK
message with related voltage
information. Press
Stop
button if wish to exit.
Figure 110: Calibration Test
Danger
:
During pillar calibration, make sure the pillar is free of disturbance or collision from
external forces.
Please use the pillar calibration project to make sure the correctness of the pillar
current and the correspoding height.