TM Palletizing Operator User’s Manual
Product Version: 1.1 Document Version: 1.2
177
2.
Press the set button to return to
measurement mode.
3.
If it detects the externally supplied
compressed air pressure lower than
0.5 Mpa, it will result in the pause of
the system.
Steps to setup vacuum suction cup of pressure sensor
The following steps are based on MP45C detected the connected pressure of the vacuum
suction cup.
1.
In measurement mode, press and
hold the button (the blue button) for
about 3 seconds to enter OUT1
operating mode.
2.
In OUT1 operating mode, use up and
down arrow buttons to select
oPS
mode (single point setting).
3.
Press the set button to enter OUT1
mode. Use up and down arrow
buttons to select
nC
(normal close)
mode.
4.
Press the set button to enter OUT2
setting. Use up and down arrow
buttons to select
oFF
mode.
5.
Press the set button to switch
response time sequence: 2.5ms
SoG
(Backlight Control).
6.
Press the set button to enter unit
setting. Use up and down arrow
buttons to select Mpa (default value).
7.
Press the set button to return to
measurement mode.