AC power installation must be performed by a skilled and instructed person. During
installation, unauthorized third parties must be prevented from turning on power through
the use of fail-safe lockout measures.
Failure to use appropriate power can lead to malfunction or failures of the robot or
hazardous situations.
Pre-Use Assessment
The following tests must be conducted before using the robot system for the first time or after any
modifications. Verify that all safety inputs and outputs are appropriately and correctly connected.
Test the emergency stop buttons.
Test that safeguard input to stop the robot system motion and the resume function.
Test the mode switches of the operational mode.
Test the 3-position enabling device, which must be continuously held to enable motion in manual
mode.
Test the System Emergency Stop outputs to stop the whole system and force into a safe state.
Test the Reset Button function to reset safety state when safety devices are triggered.
Test the Safeguard Output function to test the safeguard output when safety devices are
triggered.
Emergency Stop
If any accident or hazardous situation arises during the operation of the robot, press the Emergency
Stop switch to stop all the movements immediately. Once the robot stops all its actions, users must
ensure that all the risks are eliminated before restarting the robot manually. The Emergency Stop
Switch is only used in critical conditions. The Emergency Stop Switch will disconnect the power supply
of the robot, pillar and activate the brakes once the robot motion ceases. The indication light ring of the
robot will not flash, and the three lights from the robot stick will blink constantly. In normal operations,
simply press the Stop Button.
3-Position Enabling Device
The enabling device must be continuously held in the center-enabled position in manual mode to
permit motion of the robot system, it actives a protective stop (category 2 stop) to stop all motion of the
robot system when the enabling device is fully released or fully compressed. When the robot system is
in Auto Reset, the enabling device has no effect.
Summary of Contents for TM Palletizing Operator
Page 40: ...TM Palletizing Operator User s Manual Product Version 1 1 Document Version 1 2 40 ...
Page 182: ...TM Palletizing Operator User s Manual Product Version 1 1 Document Version 1 2 182 ...
Page 183: ...TM Palletizing Operator User s Manual Product Version 1 1 Document Version 1 2 183 ...
Page 185: ...TM Palletizing Operator User s Manual Product Version 1 1 Document Version 1 2 185 ...