TM Palletizing Operator User’s Manual
Product Version: 1.1 Document Version: 1.2
176
Appendix
– B: Vacuum Pressure Sensor Setting
The following provides a detailed vacuum pressure sensor setup guide of the adjustable flexible gripper.
Steps to setup pressure sensor
When the externally supplied compressed air source is monitored at MP45P (positive air
pressure)
1.
In measurement mode, press and
hold the button (the blue button) for
about 3 seconds to enter OUT1
operating mode.
2.
In OUT1 operating mode, use up and
down arrow buttons to select
oPS
mode (single point setting).
3.
Press the set button to enter OUT1
mode. Use up and down arrow
buttons to select
no
(normal open)
mode.
4.
Press the set button to enter OUT2
mode. Use up and down arrow
buttons to select
oFF
mode.
5.
Press the set button to switch
response time sequence: 2.5ms
SoG
(Backlight Control).
6.
Press the set button to enter unit
setting. Use up and down arrow
buttons to select Mpa (default value).
7.
Press the set button to return to
measurement mode.
Pressure setting (single-point setting mode)
1.
In measurement mode, press the set
button to enter
P-1
, and use up and
down arrow buttons to set pressure
value at 0.5 Mpa.
Summary of Contents for TM Palletizing Operator
Page 40: ...TM Palletizing Operator User s Manual Product Version 1 1 Document Version 1 2 40 ...
Page 182: ...TM Palletizing Operator User s Manual Product Version 1 1 Document Version 1 2 182 ...
Page 183: ...TM Palletizing Operator User s Manual Product Version 1 1 Document Version 1 2 183 ...
Page 185: ...TM Palletizing Operator User s Manual Product Version 1 1 Document Version 1 2 185 ...