4. Electrical Interface
General Electrical Specifications
TM Palletizing Operator TM Palletizing Distribution Box is supplied by AC power input. Refer to the
table below for the general electrical specifications.
Parameter
Min.
Typical
Max.
Unit
Input voltage*
100
-
240
VAC
External AC fuse (100V – 120V)
-
-
16
A
External AC fuse (220V – 240V)
-
-
11
A
Input frequency
43
-
63
Hz
*
If AC input 100V-199V is used as the power supply, the total power output will be automatically limited.
Table 13: AC Input Specifications of TM Palletizing Operator
Electrical Warnings and Cautions
The application design and installation of the TM Palletizing Operator should comply with the following
safety.
DANGER:
1.
Ensure all pieces of the equipment are kept dry. If water enters the equipment, disconnect
the power and contact your supplier.
2.
Only use the original cables included with the robot. If you need longer cables, contact
your supplier.
3.
Ensure that the robot is properly grounded. If the grounding is not correct, it may cause a
fire or electric shock.
WARNING:
1.
The I/O cables used for the link between the control box and other pieces of equipment
should not be longer than 30 meters, unless testing shows that longer cables are feasible.
2.
Perform installation to the electrical interfaces when the machine is shut down. Do NOT
perform any installation when the machine is powered on to avoid abnormal shutdown.
A Glance inside TM Palletizing Operator
Summary of Contents for TM Palletizing Operator
Page 40: ...TM Palletizing Operator User s Manual Product Version 1 1 Document Version 1 2 40 ...
Page 182: ...TM Palletizing Operator User s Manual Product Version 1 1 Document Version 1 2 182 ...
Page 183: ...TM Palletizing Operator User s Manual Product Version 1 1 Document Version 1 2 183 ...
Page 185: ...TM Palletizing Operator User s Manual Product Version 1 1 Document Version 1 2 185 ...