TM Palletizing Operator User’s Manual
Product Version: 1.1 Document Version: 1.2
74
Figure 27: Safety Controller SF-C21
Safety Input
Pin
Description
Function
IN1/IN2
Connected to 24V by default
•
Users may connect it to
external safeguard device
Trigger SF4 (External Safeguard-Human-
Machine Safety Settings)
•
if external safeguard device is connected
IN3/IN4
Connected to 24V by default
•
Users may connect it to
external safeguard device
IN5/IN6
Connected to 24V by default
•
Users may connect it to
external safeguard device
IN7/IN8
Connected to 24V by default
•
Users may connect it to
external safeguard device
Safety Output
Pin
Description
Function
SF0_0/SF0_1
Connected to SI10/SI11 of Safety
Controller G9SP
Trigger SF4 (External Safeguard-
Human-Machine Safety Settings)
SF0_2/SF0_3
Available for customer use
Output low when external safeguard device triggered.
Table 18: Safety Controller (SF-C21) I/O
IMPORTANT:
Assure the following steps when connecting Safety Controller to external safety devices.
1.
Power off the system
2.
Remove the pull-high 24V cables (IN1/IN2 – IN7/IN8), and then connect to external
Safety Controller (SF-C21)