X-2
Troubleshooting
The first and most important aspect of troubleshooting anything is to be systematic. Note where you
have looked and what you found.
Look first for the obvious.
•
Make a physical inspection of the entire facility. Are all necessary connections properly made?
Do you see any signs of obvious damage within the equipment?
•
Is the AC power ‘ON’ to the site and the equipment? (Check fuses and circuit breakers if
necessary.)
•
Are all the switches in the correct operating position?
•
Is the input signal present?
•
Check LCD readings for presence of forward and reflected power and 30 V DC supply levels.
The above is an aid in determining the fault if some aspect of the system is not operating. The
following table deals with quality of operation:
Symptom
Possible Fault
Correction
Horizontal bars in picture (may
roll either way depending on
phase)
AC grounding / AC
interference
Install EMI/RFI filter in AC line
Ensure modulator/processor
and power amplifier share a
common ground
Diagonal lines in picture
Interference
Install EMI/RFI filter in AC line
Determine source and
frequency of interfering signal
(spectrum analyzer may be
required)
Summary of Contents for TAV-500
Page 1: ...TAV 500 POWER AMPLIFIER NEW ADVENTURES IN BROADCASTING Technalogix ...
Page 17: ...A A 1 1 TECHNALOGIX LTD 25 W VHF LO BAND DRIVER P25 VHF L R S MCDONALD 14 SEPTEMBER 2000 ...
Page 18: ...Technalogix Ltd 25 Watt High Band VHF Pallet PA25 VHF H S Kazarian November 12 2001 B B ...
Page 19: ......
Page 20: ...Technalogix Ltd 400 Watt High Band VHF Pallet P400 VHF H R S McDonald July 30 2001 B A ...
Page 49: ...Technalogix Ltd VIII 9 Location and Function of Controls and Connectors Power Supply ...