- 19 -
10. Installation, Piping and Wiring
10-1. Installation
(1) Installation site
An installation site must be an ambient temperature of 0~40°C
and a relative humidity of lower than 90%. Install the pump at the
place where the maintenance and inspection work can be done
easily.
(2) Pump installation method
This pump is not the selfprim-
ing pump. The pump shall be
installed in a position lower
than the liquid level of the
suction tank.
Liquid level must be higher by
30 cm than the pump suction
port level. If this distance is
too short, the air may be
sucked in the pump, which
will cause abnormal wear of
pump bearing.
(3) Direction of pump
discharge port
The discharge port can be
directed as desired. However,
for efficient elimination of the
air out of the pump chamber,
it is recommended that the dis-
charge port is directed
upward.
(4) Anchoring of base
The base of the pump must be
anchored firmly.
The pump must not be mount-
ed in a vertical position.
(5) Hose preparation
The ends of the hoses should
be cut flat before connecting
them.