- 25 -
No.
5
6
Operation Step
Adjust discharge
capacity & head to
desired values.
Checkpoints during
operation
Description (Points to be Checked)
Adjust discharge side valve gradually
till desired discharge capacity and head
are obtained. Do not open or close
valves suddenly.
Note: Do not keep discharge side
valve closed for more than 1
minute.
Note: Check that pump feeds liquid
normally. If not, turn off power
immediately and eliminate
cause referring to 'Causes of
Trouble and Troubleshooting'
section (p.27).
• Be careful to prevent foreign matter
from entering pump. Foreign matter
in pump may cause impeller to be
locked, hindering liquid circulation.
Motor itself continues to rotate even
if impeller is locked. In such a case,
turn off power supply at once.
• When earth leakage breaker is acti-
vated, turn off power supply at once
and eliminate cause by referring to
'Causes of Trouble and
Troubleshooting' section.
No.
1
2
Stopping Step
Close discharge side
valve.
Turn off power
supply. (Check
stopping condition.)
Description
Close discharge side valve gradually.
Do not use electromagnetic valve for
quick closing.
Check that motor stops smoothly after
power supply is disconnected. If not,
pump should be inspected. (For
details, contact Iwaki or your dealer.)
■
Pump Stopping Procedure
■
How to store pump when it is out of use for a long time
Remove the liquid from the pump if it is to be stored for a long
time. In addition, run it with water circulating for about 5 min-
utes every 3 months to prevent rust on the motor bearing.