6.2. Standard Package Contents  

 
 

 

 

 

Item  Partnumber 

Description 

TEP-0500-IMX7 

5 inch PoE HMI PCAP touch system with NXP i.MX7 

Accessoires 

5x mounting hooks 
5x long screws (M3) 
5x mounting posts 
1x M.2 LTE module screw 
2x rubber cable grommets 
1x rubber O-ring 
1x DC power latch cable (2-pin Micro-Fit 3.0) 

 
NOTE: Pack contents might vary depending on your ordered configuration.  

 

 

Summary of Contents for TEP-0500-IMX7

Page 1: ...TEP 0500 IMX7 MODULAR HMI PRODUCT MANUAL TEP 0500 IMX7 VER 1 00 August 03 2018 ...

Page 2: ...TEP 0500 IMX7 HARDWARE MANUAL VER 1 00 AUG 03 2018 Page 2 of 27 REVISION HISTORY Revision Date Originator Notes 1 00 August 03 2018 TechNexion First public release ...

Page 3: ...15 3 6 LED Light Indicator 15 3 7 USB OTG Type C Connector 16 3 8 MicroSD Connector 16 3 9 Nano SIM Connector 16 3 10 Gigabit Ethernet Interface 17 3 11 USB Host Connector 17 3 12 Power Input Connector 17 3 13 Grounding 18 3 14 Antenna Holes 18 4 Internal Connectors and Expansion Options 19 4 1 RTC Battery Connector 19 4 2 M 2 KEY B 3G 4G LTE Module Connector 20 4 3 SW3 Panel Backlight Switch 20 4...

Page 4: ...d prevent proper operation Unauthorized modifications or attachments could damage the device and may violate regulations governing radio devices These suggestions apply equally to your device battery charger or any enhancement If any device is not working properly take it to the nearest authorized service facility for service Regulatory information Disposal of Waste Equipment by Users in Private H...

Page 5: ...TEP 0500 IMX7 HARDWARE MANUAL VER 1 00 AUG 03 2018 Page 5 of 27 2 TEP 0500 IMX7 Product Overview 2 1 Functional Block Diagram ...

Page 6: ...TEP 0500 IMX7 HARDWARE MANUAL VER 1 00 AUG 03 2018 Page 6 of 27 2 2 Dimensions The following figure shows the TEP 0500 IMX7 dimensions unit mm ...

Page 7: ...ut out Dimensions For Mounting Though a Panel The TEP 0500 IMX7 can be mounted on the front or the back of the panel In order to mount it from the front a nominal rectangular cutout must be made in the panel The following drawing shows the dimensions of the cut out area unit mm ...

Page 8: ...No Description No Description 1 RS XXX Serial Port connector 10 Antenna hole 2 CANBus CAN Bus connector 11 USB OTG Type C connector 3 GPIO1 connector 12 MicroSD cardslot 4 GPIO2 connector 13 Nano SIM cardslot 5 Antenna hole 14 LAN2 RJ45 connector 6 Antenna hole 15 USB Host connector 7 S1 Boot Select button 16 LAN1 RJ45 and PoE optional 8 Reset button 17 Power Input connector 9 LED Light indicator ...

Page 9: ...X Serial Port connector 10 Antenna hole 2 CANBus CAN Bus connector 11 USB OTG Type C connector 3 GPIO1 connector 12 MicroSD cardslot 4 GPIO2 connector 13 Nano SIM cardslot 5 Antenna hole 14 LAN2 RJ45 connector 6 Antenna hole 15 USB Host connector 7 S1 Boot Select button 16 LAN1 RJ45 and PoE optional 8 Reset button 17 Power Input connector 9 LED Light indicator 18 Grounding screw ...

Page 10: ...rial Port connector 10 Antenna hole 2 CANBus CAN Bus connector 11 USB OTG Type C connector 3 GPIO1 connector 12 MicroSD cardslot 4 GPIO2 connector 13 Nano SIM cardslot 5 Antenna hole 14 LAN2 RJ45 connector 6 Antenna hole 15 USB Host connector 7 S1 Boot Select button 16 LAN1 RJ45 and PoE optional 8 Reset button 17 Power Input connector 9 LED Light indicator 18 Grounding screw ...

Page 11: ...al connectors switches and internal expansion options It is necessary to remove the Power Expansion module to access several switches headers and connectors Rear view opened device with the Power Expansion module A Power Expansion Module Internal Connectors and Switches No Description No Description A RTC Battery connector ...

Page 12: ...ansion module A E B C D Internal Connectors and Switches No Description No Description A RTC Battery connector D SW2 Panel switch B M 2 KEY B 3G 4G LTE module connector USB E Power Expansion module connector C SW3 Panel switch NOTE Items marked with are accessible only after removing the Power Expansion module ...

Page 13: ...iption Device 1 GND Ground 2 SERIAL1A_TXD Port 1A Transmit data output ttymxc1 3 SERIAL1A_RXD Port 1A Receive data input ttymxc1 4 NC 5 NC 6 GND Ground 7 SERIAL1B_TXD Port 1B Transmit data output ttymxc2 8 SERIAL1B_RXD Port 1B Receive data input ttymxc2 9 NC 10 NC Header on TEP 0500 IMX7 Molex 43045 1012 10 pin Micro Fit 3 0 Cable receptacle Molex 43025 1000 10 pin Micro Fit 3 0 plug with crimp co...

Page 14: ...B_N CAN Bus 1B low 24 24V can1 11 CAN1B_TERM_N To enable CAN1B Termination bridge with CAN1B_N can1 12 NC Header on TEP 0500 IMX7 Molex 43045 1212 12 pin Micro Fit 3 0 Cable receptacle Molex 43025 1200 12 pin Micro Fit 3 0 plug with crimp contact Molex 43030 0007 3 3 Digital I O Connectors GPIO1 GPIO2 The TEP 0500 IMX7 has two non galvanic isolated GPIO Expansion headers with the following pinout ...

Page 15: ...quires software modification Please connect with TechNexion support team for more details Header on TEP 0500 IMX7 Molex 43045 0812 8 pin Micro Fit 3 0 Cable receptacle Molex 43025 0800 8 pin Micro Fit 3 0 plug with crimp contact Molex 43030 0007 3 4 S1 Button The TEP 0500 IMX7 by default boots the unit from internal flash storage eMMC By pressing the S1 button before applying power to the unit and...

Page 16: ...cardslot which is connected to the NXP i MX7 integrated Ultra Secured Digital Host Controller uSDHC The following main features are supported by uSDHC Compatible with the MMC System Specification version 4 2 4 3 4 4 4 41 5 0 Conforms to the SD Host Controller Standard Specification version 3 0 Compatible with the SD Memory Card Specification version 3 0 and supports the Extended Capacity SD Memory...

Page 17: ...a Receive Data 4 MDI2 5 MDI2 6 MDI1 Receive Data Receive Data 7 MDI3 8 MDI3 3 11 USB Host Connector The TEP 0500 IMX7 has a standard single USB Host connector USB 2 0 signals only to connect to a USB peripheral such as a keyboard mouse USB storage device or USB hub 3 12 Power Input Connector The TEP 0500 IMX7 can be powered either over the DC INPUT connector or PoE over the RJ45 LAN1 port NOTE Do ...

Page 18: ...ence on the device The earth connection will have to be done using the grounding screw The screw for the ground connection is marked with an engraved ground symbol 3 14 Antenna Holes There are five antenna holes two on the rear side one on the right side two on the top side available They come fitted with breakaway metal tabs In order to utilize them the tabs must be removed by carefully using pin...

Page 19: ...on No Description A RTC Battery connector D SW2 Panel switch B M 2 KEY B 3G 4G LTE module connector USB E Power Expansion module connector C SW3 Panel switch NOTE Items marked with are accessible only after removing the Power Expansion module 4 1 RTC Battery Connector The TEP 0500 IMX7 has an internal RTC backup battery connector Marked A Pin Signal Description 1 GND Ground 2 RTC_VCC 3V connect to...

Page 20: ...ch The TEP 0500 IMX7 has an internal SW3 Panel Backlight switch Marked C Always use the default settings Pin 5 Panel default 7 Panel 1 2 OFF ON 4 4 SW2 Panel Scanning Direction Switch The TEP 0500 IMX7 has an internal SW2 Panel Scanning Direction switch Marked D Always use the default settings Pin 5 Panel default 7 Panel Description 1 8 ON OFF Down to Up 2 7 OFF OFF Up do Down 3 6 OFF OFF Left to ...

Page 21: ...EP 0500 IMX7 The material in area of the mounting must provide sufficient strength for safe mounting of this device 5 1 VESA Mounting The TEP 0500 IMX7 is compatible with the VESA MIS C Standard 35 75mm hole pattern There are 4 VESA MIS C M4 mounting holes on the rear side of the device M4 screw holes are a depth of 4mm 1 2 3 4 ...

Page 22: ...low the steps below to secure the clips Prepare mounting hook post and screw M3 Step 1 Locate all removable tabs on the rear side of your device and use pincers or pliers to remove the tabs Step 2 3 Press the mounting clip into the holes at an angle and slowly straighten it Step 4 5 Then tighten the screw to the surface Step 6 Repeat the steps for all clips required to secure your device ...

Page 23: ... required to secure this device 1 2 3 4 8 7 6 5 Please follow the steps below to properly install the waterproof rubber O ring Prepare your device and O ring Step 1 2 First align the O ring with the groove and press the O ring into the corners of the O ring groove Step 3 4 Then press it into the center Step 5 Finally stretch it uniformly around the O ring groove Step 6 Do not pull from one side an...

Page 24: ...creation rules Custom part numbers carry minimum order quantities MOQ Please connect with your TechNexion distributor or account manager for conditions and availability Part number format TEP0500 IMX7x Rxx Exx Lxxx xxxx Interface Code Description Processor IMX7S NXP i MX7Solo IMX7D NXP i MX7Dual Memory R05 512MB DDR3L R10 1GB DDR3L R20 2GB DDR3L Storage E04 eMMC 4GB E08 eMMC 8GB EXX eMMC other cap...

Page 25: ...iption 1 TEP 0500 IMX7 5 inch PoE HMI PCAP touch system with NXP i MX7 2 Accessoires 5x mounting hooks 5x long screws M3 5x mounting posts 1x M 2 LTE module screw 2x rubber cable grommets 1x rubber O ring 1x DC power latch cable 2 pin Micro Fit 3 0 NOTE Pack contents might vary depending on your ordered configuration ...

Page 26: ...nts or other intellectual property of the third party or a license from TechNexion under the patents or other intellectual property of TechNexion TechNexion products are not authorized for use in safety critical applications such as life support where a failure of the TechNexion product would reasonably be expected to cause severe personal injury or death unless officers of the parties have execut...

Page 27: ...this publication To the extent permitted by law no liability including liability to any person by reason of negligence will be accepted by TechNexion Ltd its subsidiaries or employees for any direct or indirect loss or damage caused by omissions from or inaccuracies in this document TechNexion Ltd reserves the right to change details in this publication without notice Product and company names her...