Channel Values and Functions – 3 Channel Mode 

 
 

CH 1   : Dimmer 

Sets the intensity of the White 
LED output.   
 
 
 
  

CH 2   : Strobe 

Sets relative speed of flashing.  
 
 
 
 
 

CH 3   : Dimmer Curve 

Selects the dimmer curve to 
use. With no value present, 
defaults to the fixture setting.    

 
 
 
 
 
 
 
 
 
 
 
 
 

Dimming Curves 

 
 
 
 
 
 
 

 
LINEAR: 

the increase in light intensity appears to be linear as DMX value is increased.

 

SQUARE LAW: 

light intensity control is finer at low levels and coarser at high levels

 

INVERSE SQUARE LAW: 

light intensity control is coarser at low levels and finer at high levels 

S-CURVE: 

light intensity control is fine at low levels and high levels and coarser at medium 

levels. 

CH 1 – White 

DMX Value 

Function 

0 No 

Output 

1-255 

Intensity - Off to Full On 

CH 2 – Strobe 

DMX Value 

Function 

On – no flash 

1-255 Flash 

speed 

CH 3 – Dimmer Curve 

DMX Value 

Function 

0-15 

curve selected on fixture itself 

16-45 

curve linear response halogen 

46-75 

curve square response halogen 

76-105 

curve inverse square response 
halogen 

106-135 

curve S response halogen 

136-165 

curve linear response LED 

166-195 

curve square response LED 

196-225 

curve inverse square response 
LED 

226-255 

curve S response LED 

Summary of Contents for DL-FLEXILED100W/B

Page 1: ...Information specifically for DL FLEXILED100W B V1 0 This manual contains important information Please read before operating fixture ...

Page 2: ...ed to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an RMA The RMA number must be clearly listed on the shipping label Due care must be exercised in packing all merchandise to be returned All repairs must be accompanie...

Page 3: ...trol 7 DMX Data Connection 7 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 9 DMX Channel Assignments 9 1 Channel Mode 01 9 3 Channel Mode 03 9 Channel Values and Functions 3 Channel Mode 10 CH 1 Dimmer 10 CH 2 Strobe 10 CH 3 Dimmer Curve 10 Dimming Curves 10 Maintenance 11 Accessory Items sold separately 11 Troubleshooting 12 DMX 512 Background 12 ...

Page 4: ...ing hole Physical Color Black Size 12 W x 8 75 H x 13 L Weight 9 5 lbs 4 32 kgs Housing Material Aluminum Environmental Location Indoor Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Auto Ranging from 100 250vAC 50 60Hz Rated Power 120W Fuses 2 amp mini size 5 2x20mm Control Digital Protocol USITT DMX512 1990 Channels 1 and 3 maximum Data...

Page 5: ... of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non original packing and or cartons Power Do not apply power to the fixture until power source is verified For protection against electric shock fixture must be connected to suitable earth ground Make s...

Page 6: ...output beam of the fixture By using certain light diffusers it is possible to create different desired lighting effects A desired effect might be a softer or diffused light beam Many diffraction materials are available to create different beam angles with minimal light output losses The following refers to the different modes that are available on this fixture via the LCD Control Panel display All...

Page 7: ...o a Start Address of 4 it would use data from channels 4 5 and 6 Choose a Start Address so the channels used do not overlap with other fixtures In some cases it may be desirable to set two or more same type fixtures to the same Start Address In this case the fixtures will be slaved together and respond to the same data Because all fixtures see the same data fixtures may be set to any address witho...

Page 8: ... adapters or building adapter cables Numbers designating each pin can be found on connectors Converting between the two XLR types is done in a pin to pin fashion Connect the shields to pin 1 then connect pin 2 to pin 2 and pin 3 to pin 3 regardless of either connector s gender or pin count No connection is made to Pins 4 5 5 Pin XLR Plug Pin 1 GND Sheild Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N...

Page 9: ...lable for a Start Address is found by adding the previous fixture s Start Address to its channel requirement 1 3 4 To maximize channel usage we will leave no empty channels between fixtures so the second Start Address is set to DMX channel 4 and that fixture occupies channels 4 thru 6 The third fixture will be addressed 4 3 7 and occupy channels 7 thru 9 The last fixture is addressed 7 3 10 and wi...

Page 10: ...tensity control is coarser at low levels and finer at high levels S CURVE light intensity control is fine at low levels and high levels and coarser at medium levels CH 1 White DMX Value Function 0 No Output 1 255 Intensity Off to Full On CH 2 Strobe DMX Value Function 0 On no flash 1 255 Flash speed CH 3 Dimmer Curve DMX Value Function 0 15 curve selected on fixture itself 16 45 curve linear respo...

Page 11: ...s or effects 3 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 4 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description CLAMP MEGA B Mega Heavy Duty Aluminum Clamp Black CLAMP CBHALF Half Cheeseborough Coupler 300kg Max Load SAFETYCABLE18B Safety Cable...

Page 12: ... all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard DMX transmission This start code is transparent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shie...

Reviews: