background image

 2

IMPORTANT INFORMATION

 

 
 

Save original packing and documentation for warranty, service and return issues

 
 
Limited Warranty: This warranty covers defects or malfunctions in this equipment.  This warranty lasts 
for a period of one year from date of purchase.  It is the owner’s responsibility to provide invoices for 
proof of purchase, purchase date and dealer or distributor.  If purchase date can not be provided, 
warranty period will start at manufacture date.  It is the sole discretion of Techni-Lux to repair or replace 
parts or equipment.   All shipping will be paid by purchaser.  This warranty does not cover lamps, fuses, 
belts, power semiconductors, relays, cleaning, standard maintenance adjustments or normal wear items 
or any problem resulting from the following: improper wiring, incorrect voltage (including low or over 
voltage conditions and lightning), abuse, misuse, improper maintenance or an act of God or damage 
resulting from shipping.  Warranty will be null and void if the product is altered, modified, misused, 
damaged, or subjected to unauthorized repairs.  Lamps are covered by relevant manufacturer warranty. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to 
state.  Any liability for consequential and incidental damages is expressly disclaimed.  No other warranty, 
expressed or implied is made.  Techni-Lux liability in all events is limited to, and shall not exceed, the 
purchase price paid. 
 
Returning equipment and Repairs:  All returns must be accompanied by a Return Merchandise 
Authorization (RMA) number and sent pre-paid.  Contact the dealer or Techni-Lux directly to obtain an 
RMA.  The RMA number must be clearly listed on the shipping label.  Due care must be exercised in 
packing all merchandise to be returned.  All repairs must be accompanied by a written explanation of the 
claimed problem or error encountered.  Techni-Lux is solely responsible for determining a product’s 
eligibility for coverage under warranty.  If returning for consideration of credit, all accessories and 
documentation, original protective material and cartons must be included and the equipment, packing 
and carton must be in new resalable condition. Credit for returned merchandise will be issued at the 
lowest current price and is subject to a restocking fee.  No returns accepted on discontinued items.  
Techni-Lux is not responsible for merchandise damaged in transit and reserves the right to refuse any 
return that is damaged by the carrier, not accompanied by a Return Authorization Number (RMA#) or 
sent by freight collect.   
 
Claims:  All claims must be made within seven (7) days of receipt of merchandise.  Any physical damage 
must be reported to carrier upon receipt of merchandise. 
 
 

Please record the following information for future reference: 
Model Number:  

DL-FLEXILED100W/B 

 

Serial Number: ________________________________________ 

 

Dealer: ______________________________________________ 

 

Date of Purchase: ______________________________________ 

 
 

www.Techni-Lux.com

 

 
 

Summary of Contents for DL-FLEXILED100W/B

Page 1: ...Information specifically for DL FLEXILED100W B V1 0 This manual contains important information Please read before operating fixture ...

Page 2: ...ed to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an RMA The RMA number must be clearly listed on the shipping label Due care must be exercised in packing all merchandise to be returned All repairs must be accompanie...

Page 3: ...trol 7 DMX Data Connection 7 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 9 DMX Channel Assignments 9 1 Channel Mode 01 9 3 Channel Mode 03 9 Channel Values and Functions 3 Channel Mode 10 CH 1 Dimmer 10 CH 2 Strobe 10 CH 3 Dimmer Curve 10 Dimming Curves 10 Maintenance 11 Accessory Items sold separately 11 Troubleshooting 12 DMX 512 Background 12 ...

Page 4: ...ing hole Physical Color Black Size 12 W x 8 75 H x 13 L Weight 9 5 lbs 4 32 kgs Housing Material Aluminum Environmental Location Indoor Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Auto Ranging from 100 250vAC 50 60Hz Rated Power 120W Fuses 2 amp mini size 5 2x20mm Control Digital Protocol USITT DMX512 1990 Channels 1 and 3 maximum Data...

Page 5: ... of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non original packing and or cartons Power Do not apply power to the fixture until power source is verified For protection against electric shock fixture must be connected to suitable earth ground Make s...

Page 6: ...output beam of the fixture By using certain light diffusers it is possible to create different desired lighting effects A desired effect might be a softer or diffused light beam Many diffraction materials are available to create different beam angles with minimal light output losses The following refers to the different modes that are available on this fixture via the LCD Control Panel display All...

Page 7: ...o a Start Address of 4 it would use data from channels 4 5 and 6 Choose a Start Address so the channels used do not overlap with other fixtures In some cases it may be desirable to set two or more same type fixtures to the same Start Address In this case the fixtures will be slaved together and respond to the same data Because all fixtures see the same data fixtures may be set to any address witho...

Page 8: ... adapters or building adapter cables Numbers designating each pin can be found on connectors Converting between the two XLR types is done in a pin to pin fashion Connect the shields to pin 1 then connect pin 2 to pin 2 and pin 3 to pin 3 regardless of either connector s gender or pin count No connection is made to Pins 4 5 5 Pin XLR Plug Pin 1 GND Sheild Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N...

Page 9: ...lable for a Start Address is found by adding the previous fixture s Start Address to its channel requirement 1 3 4 To maximize channel usage we will leave no empty channels between fixtures so the second Start Address is set to DMX channel 4 and that fixture occupies channels 4 thru 6 The third fixture will be addressed 4 3 7 and occupy channels 7 thru 9 The last fixture is addressed 7 3 10 and wi...

Page 10: ...tensity control is coarser at low levels and finer at high levels S CURVE light intensity control is fine at low levels and high levels and coarser at medium levels CH 1 White DMX Value Function 0 No Output 1 255 Intensity Off to Full On CH 2 Strobe DMX Value Function 0 On no flash 1 255 Flash speed CH 3 Dimmer Curve DMX Value Function 0 15 curve selected on fixture itself 16 45 curve linear respo...

Page 11: ...s or effects 3 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 4 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description CLAMP MEGA B Mega Heavy Duty Aluminum Clamp Black CLAMP CBHALF Half Cheeseborough Coupler 300kg Max Load SAFETYCABLE18B Safety Cable...

Page 12: ... all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard DMX transmission This start code is transparent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shie...

Reviews: