background image

 9

DMX Start Address 

To place the fixture in DMX mode, press the MODE key, then using the UP/DOWN keys 
get to the Addr Menu Option. Press ENTER and using the UP/DOWN buttons, set the 
start address number for this particular unit in the DMX chain. Once selected, press 
ENTER again to save your selection.  More than one fixture may have the same start 
address, but they will behave the same. Giving a unique start address that does not 
overlap with any other units allows you to individually control that fixture’s features fully. 
Never allow channels to overlap.  You will need to select the number of channels you 
wish the fixture to use first.  Your choices are 1 or 3 channel modes.  This will determine 
the spacing of channels you will need to avoid overlapping of channels when selecting 
your start addresses. 

 

Example

 

Select Start Addresses for 4 fixtures each requiring 3 channels of DMX (3 

channel mode).

 

For this example, start with the first unit set to the first possible Start Address = 

1

.  This fixture 

occupies DMX channels 1 thru 3.  The next DMX channel available for a Start Address is found 
by adding the previous fixture’s Start Address to its channel requirement: 1+3=4.  To maximize 
channel usage, we will leave no empty channels between fixtures so the second Start Address is 
set to DMX channel 4 and that fixture occupies channels 4 thru 6.  The third fixture will be 
addressed 4+3=7 and occupy channels 7 thru 9.  The last fixture is addressed 7+3=

10

 and will 

occupy channels 10 thru 12.  Thus, 4 fixtures using 3 channels each have Start Addresses of 

1, 

4, 7

 and 

10

 and the next free channel in the system is 10+3=13.  

 
 

DMX Channel Assignments 

This fixture features 2 different DMX Channel modes.  A 1 and 3 channel mode.  Using 
the 3 channel mode provides the most features, however it takes up the most channels 
of DMX. The different channel assignments are shown below. 

The factory default is the 

3 channel mode “03”.

 We will provide a full description of the values and functions of 

the 3 channel mode only. All other modes of less channels, do the same functions 
described within the 3 channel mode. 

Note that the channel order maybe different for 

each of the modes.

    

 

 

1 Channel Mode “01”

 

 
 
 
 

3 Channel Mode “03”

 

 

 

 
 
 
 
 
 
 
 

Channel Function 

White Dimmer (0-255) 

Channel Function 

White Dimmer (0-255) 

Flash Speed (0-255) 

Dimmer Curve (0-255) 

Summary of Contents for DL-FLEXILED100W/B

Page 1: ...Information specifically for DL FLEXILED100W B V1 0 This manual contains important information Please read before operating fixture ...

Page 2: ...ed to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an RMA The RMA number must be clearly listed on the shipping label Due care must be exercised in packing all merchandise to be returned All repairs must be accompanie...

Page 3: ...trol 7 DMX Data Connection 7 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 9 DMX Channel Assignments 9 1 Channel Mode 01 9 3 Channel Mode 03 9 Channel Values and Functions 3 Channel Mode 10 CH 1 Dimmer 10 CH 2 Strobe 10 CH 3 Dimmer Curve 10 Dimming Curves 10 Maintenance 11 Accessory Items sold separately 11 Troubleshooting 12 DMX 512 Background 12 ...

Page 4: ...ing hole Physical Color Black Size 12 W x 8 75 H x 13 L Weight 9 5 lbs 4 32 kgs Housing Material Aluminum Environmental Location Indoor Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Auto Ranging from 100 250vAC 50 60Hz Rated Power 120W Fuses 2 amp mini size 5 2x20mm Control Digital Protocol USITT DMX512 1990 Channels 1 and 3 maximum Data...

Page 5: ... of the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non original packing and or cartons Power Do not apply power to the fixture until power source is verified For protection against electric shock fixture must be connected to suitable earth ground Make s...

Page 6: ...output beam of the fixture By using certain light diffusers it is possible to create different desired lighting effects A desired effect might be a softer or diffused light beam Many diffraction materials are available to create different beam angles with minimal light output losses The following refers to the different modes that are available on this fixture via the LCD Control Panel display All...

Page 7: ...o a Start Address of 4 it would use data from channels 4 5 and 6 Choose a Start Address so the channels used do not overlap with other fixtures In some cases it may be desirable to set two or more same type fixtures to the same Start Address In this case the fixtures will be slaved together and respond to the same data Because all fixtures see the same data fixtures may be set to any address witho...

Page 8: ... adapters or building adapter cables Numbers designating each pin can be found on connectors Converting between the two XLR types is done in a pin to pin fashion Connect the shields to pin 1 then connect pin 2 to pin 2 and pin 3 to pin 3 regardless of either connector s gender or pin count No connection is made to Pins 4 5 5 Pin XLR Plug Pin 1 GND Sheild Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N...

Page 9: ...lable for a Start Address is found by adding the previous fixture s Start Address to its channel requirement 1 3 4 To maximize channel usage we will leave no empty channels between fixtures so the second Start Address is set to DMX channel 4 and that fixture occupies channels 4 thru 6 The third fixture will be addressed 4 3 7 and occupy channels 7 thru 9 The last fixture is addressed 7 3 10 and wi...

Page 10: ...tensity control is coarser at low levels and finer at high levels S CURVE light intensity control is fine at low levels and high levels and coarser at medium levels CH 1 White DMX Value Function 0 No Output 1 255 Intensity Off to Full On CH 2 Strobe DMX Value Function 0 On no flash 1 255 Flash speed CH 3 Dimmer Curve DMX Value Function 0 15 curve selected on fixture itself 16 45 curve linear respo...

Page 11: ...s or effects 3 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 4 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description CLAMP MEGA B Mega Heavy Duty Aluminum Clamp Black CLAMP CBHALF Half Cheeseborough Coupler 300kg Max Load SAFETYCABLE18B Safety Cable...

Page 12: ... all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard DMX transmission This start code is transparent to the user and is handled by the controller The physical signals are transmitted using a twisted pair of wires and a common shie...

Reviews: