background image

 

 

 

 

                                                                                              4 

 

 

To use the FM-10 machine via DMX, set the start address on the remote digitally.  It uses 3 channels of 

standard DMX protocol to control its functions. Connect DMX to machine via the DMX IN 3-pin XLR 

connector located on the back of the unit. Pass thru DMX out is provided via 3-pin XLR also. 

DMX CHANNELS: 

 

 

 

DMX VALUES 

>> FUNCTION 

Ch. 1 

Duration (the on time) 

 

0-10   

 

 

>> Off 

 

 

 

 

 

 

 

 

 

 

11-240 

 

 

>> Long to Short 

 

 

 

 

 

 

 

 

 

 

241-255   

 

>> Full "ON" Bump at 100% 

Ch. 2 

Output Volume 

 

 

0-255 

 

 

>> Low to Maximum 

Ch. 3   

Interval (cycle time) 

 

0-255 

 

 

>> Short to Long   

 

FM-9 using remote ZC-4 

 

ZC-4: 10 meter wired timer remote on FM-9, provides the ability to set different cycle times.  Both the 

interval and duration may be adjusted using the two turn buttons. It can operate in automatic timer mode or in 

manual mode.  Connection of remote is via a 5-pin DIN connector located on the back of the unit. 

 

Cleaning your fog machine regularly will help reduce costly part replacement and repair 
charges and prolong its life. 

Maintenance 

Do not allow the fog liquid to become contaminated. Always replace the caps on the fog liquid container and the 

fog machine liquid tank immediately after filling. 

 

After every 40 hours of continuous operation. It is recommended to run a cleaning solution composed of 80% 

distilled water 20% white vinegar through the system to prevent the accumulation of particulate matter in the 

heating element. The recommend-cleaning regimen is as follows: 

1.

 

While unit is unplugged and cool, if removal nozzle type, unscrew nozzle at very front of unit and clean out 

debris with vinegar and a pipe cleaner, making sure that the hole is free of any clogging. 

2.

 

Empty all fog fluid from machine. Rinse tank with clean water. Add above cleaning solution to tank. Plug unit in 

and begin warm up. 

3.

 

Run unit in a well-ventilated area until tank is empty. 

4.

 

Replace nozzle. 

5.

 

Cleaning is now complete, refill with fog liquid. 

 

Notes

: All fog machines are prone to clogging due to the thick consistency of fog fluid and the high temperature 

at which it vaporizes. However, a properly maintained fog machine should provide an extended term of reliable use.  

Keeping the fluid container clean will also help prolong fog machine life. 

Clean with a dry cloth only. 

Store in dry place. Before storing for a long period of time, run distilled water through it. 

Save these instructions. 

Summary of Contents for FM-9

Page 1: ...types of water based fog fluid formulas The fluids used must be compatible with this machine Never use in a confined or non ventilated area THIS MACHINE IS DESIGNED TO USE WATER BASED FOG FLUID ONLY Specifications MODEL FM 9 FM 10 VOLTAGE 110V 125V 60Hz 110V 125V 60Hz POWER 1000W 1500W FUSE 10A 125V 15A 125V WARMUP TIME 5MIN 15MIN SPRAY DISTANCE 5M 10M OUTPUT 15000 cuft min 25000 cuft min TANK CAP...

Page 2: ...or service it DANGER OF EXPLOSION Never add flammable liquids of any kind oil gas perfume alcohol to the fog liquid Pay attention to all warning labels and instructions printed on the exterior of your fog machine Use only the high quality water based fog liquid that your dealer recommends Other fog liquids may cause clogging or spitting which could also cause slippery floors Techni Lux ELITE Foggi...

Page 3: ...CONTROL OPERATION If your model includes a mounting bracket designed for overhead installation it may be installed at floor level or suspended overhead If the unit is to be mounted using the bracket it is important that the fog does not shoot directly at anyone s face Whatever installation method you choose do not allow the unit to have more than a 15 degree angle of inclination Important Always m...

Page 4: ...id container and the fog machine liquid tank immediately after filling After every 40 hours of continuous operation It is recommended to run a cleaning solution composed of 80 distilled water 20 white vinegar through the system to prevent the accumulation of particulate matter in the heating element The recommend cleaning regimen is as follows 1 While unit is unplugged and cool if removal nozzle t...

Reviews: