37.4163.335.0 10/2007
EG
I
F
D
E
P
GR
INSTALLATION INSTRUCTIONS
- Split system air conditioner -
This air conditioner uses the new refrigerant R410A
PARTS
FIGURE
Q.TY
PARTS
FIGURE
Q.TY
PARTS
FIGURE
Q.TY
PARTS
FIGURE
Q.TY
PARTS
FIGURE
Q.TY
ACCESSORIES SUPPLIED WITH THE UNIT
RAWL PLUG
4
1
1
2
1
4
1
1
2
CLAMPER
REMOTE CONTROL
AAA ALKALINE
BATTERY
REMOTE CONTROL
UNIT HOLDER
TAPPING
SCREW 4x30
FULL SCALL
DIAGRAM
BRACKET
SIDE PANELS
(LEFT AND RIGHT)
4
1
4
4
TAPPING
SCREW 4,2x9,5
DRAIN
ELBOW *
DRAIN
CAP *
CUSHION
RUBBER *
*
Packed in the outdoor unit.
ACCESSORY FOR UNDER - CEILING OR WALL INSTALLATION (ALREADY INSTALLED)
BRACKET
2
WASHER - SPRING WASHER
4
BOLT M8
4
DECLARATION OF CONFORMITY
This product is marked as it satisfies Directives:
– Low voltage no.
2006/95/CE
.
– Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC
and 93/68 EEC.
This declaration will become void in case of misuse and/or non
observance though partial of manufacturer's installation and/or
operating instructions.
Tools required for installation (not supplied)
1
1. Standard screwdriver
1
2. Phillips head screwdriver
1
3. Knife or wire stripper
1
4. Tape measure
1
5. Level
1
6. Sabre saw or key hole
saw
1
7. Hacksaw
1
8. Core bits ø 5
1
9. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
16. Hex. key
OPERATING LIMITS
L
Cooling Maximum conditions
Outdoor temperature :
43°C D.B.
Room temperature
:
32°C D.B. / 23°C W.B.
L
Cooling Minimum conditions
Outdoor temperature :
19°C D.B.
Room temperature
:
19°C D.B. / 14°C W.B.
L
Heating Maximum conditions
Outdoor temperature :
24°C D.B. / 18°C W.B.
Room temperature
:
27°C D.B.
L
Heating Minimum conditions
Outdoor temperature :
–15°C W.B.
Room temperature
:
16°C B.S.
F-GAS Regulation (EC) No. 842/2006
Do not vent R410A into atmosphere: R410A is a fluorinated
greenhouse gas, covered by Kyoto Protocol, with a Global
Warming Potential (GWP) = 1975.
Power Supply:
220 - 240 V ~ 50 Hz
WARNING
Read the yellow instruction sheet attached to the outdoor
units.
Model Combinations
Combine indoor and outdoor units only as listed below.
Indoor Units
Outdoor Units
KPAF127R5I
GRF127R5I
KPAF187R5I
GRF186R5I
KPAF247R5I
GRF246R5I
KPAF128MR5I
FOR “MULTI SPLIT” INSTALLATION SEE
“MULTI DC INVERTER COMBINATIONS
TABLE”