8
Outdoor Unit GRV77L5
Controller PCB
Part No. POW-CL128E
Control circuit fuse 250 V 3.15 A
Compressor
Type Rotary (Hermetic)
Compressor model C-1RN60H5H 80206045
Nominal output W 600
Compressor oil ... Amount cc FV68S ... 370
Coil resistance (Ambient temp. 25°C)
Ω
C–R : 4.66
C–S : 8.89
Safety devices Type External(OLR A) External(OLR T)
Overload relay MRA99059-9201 CS-7C115
Operating temp. Open °C 145±5 115±3
Close °C 69±11 95±5
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 13A —
Run capacitor µF 17.5
VAC 400
Crank case heater —
Fan & Fan Motor
Type Propeller
Q'ty ... Dia. 1 ... ø400
Fan motor model ... Q'ty UE6T-21D5PA-S ... 1
No. of poles ... rpm (230 V, High) 6 ... 650
Nominal output W 20
Coil resistance (Ambient temp. 20°C)
Ω
BRN-WHT : 381.2
WHT-VLT : 268.1
VLT-YEL : 49.71
YEL-PNK : 84.6
Safety devices Type Internal fuse
Operating temp. Open °C 165±3
Close °C —
Run capacitor µF 1.5
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 1
Fin pitch mm 1.3
Face area m
2
0.377
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2-2-2. Outdoor Unit