FAN ONLY
COOLING Model Only
A) HOW TO SET THE OFF TIME
SWITCH BUTTON NR. 3 OFF
1. Press the PROGRAM button once.
The OFF and time indications flash.
2. Press the HH button until the desired hour is
displayed.
Press the MM button until the desired
minutes are displayed. The display will
change automatically back to show the
present time after 10 sec.
3. Press the ON/OFF button to start the air
conditioner.
4. Press the TIMER SELECT button to set
OFF time.
B) HOW TO SET THE ON TIME
SWITCH BUTTON NR. 3 OFF
1. Press the PROGRAM button twice.
The ON and time indications flash.
2. Press the HH button until the desired hour
is displayed.
Press the MM button until the desired
minutes are displayed. The display will
change automatically back to show the present
time after 10 sec.
3. Press the ON/OFF button to start the air
conditioner.
4. Press the TIMER SELECT button four times
to set ON time.
C) HOW TO SET A PROGRAM FOR DAILY
ON/OFF OPERATION
1. Set the timer ON/OFF as shown in A) and
B).
2. Press the ON/OFF button to start the air
conditioner.
3. Press twice the TIMER SELECT button to set
the ON/OFF combination timer.
The above mentioned data make reference to the conditioner
operating when the sensor on the remote control unit is ON. (Refer
to “TEMPERATURE SENSOR SELECTOR”). If the sensor on the
indoor unit is being used then actual operation will slightly differ
from that described in the above tables. ( Sign shown on the
remote control unit display).
ADJUSTING THE FAN SPEED
AUTOMATIC
Simply set the FAN SPEED selector to the “AUTO” position .
A microcomputer automatically controls the fan speed when the
AUTO mode is selected. When the air conditioner starts operating,
the difference between the room temperature and the set
temperature is detected by the microcomputer which then
automatically switches the fan speed to the most suitable level.
WHEN DIFFERENCE BETWEEN
ROOM TEMPERATURE AND SET
FAN SPEED
TEMPERATURE IS
Cooling and
2 °C and over
High
dehumidifying modes: Between 2 and 1 °C
Medium
Below 1 °C
Low
2 °C and over
High
Heating mode:
Below 2 °C
Medium
High speed
Med. speed
Low speed
MANUAL
If you want to manually adjust speed just set the FAN SPEED
selector as desired.
NOTE
If you want to make air circulate without any temperature control,
follow these steps:
1. Press MODE button until the fan sign appears on the
display.
2. Press the ON/OFF operation button and switch the air
conditioner ON.
1°C
1°C
30 min.
30 min.
TIME
Setting temperature
Room temperature
COOLING AND DEHUMIDIFYING
2°C
2°C
p
p
30 min.
30 min.
TIME
Setting temperature
Room temperature
HEATING
AIR CONDITIONER
TEMP.
TIMER
1 HR.
ON I /OFF
MODE
FLAP
FAN SPEED
SELECT
HH
MM
TIME SET
SETBACK
NIGHT
ACL
OFF
E
ON
CLOCK
TIMER
SELECT
A/C
3
1
2
SETTING THE TIMER
AIR CONDITIONER
TEMP.
TIMER
1 HR.
ON I /OFF
BATTERIES
MODE
FLAP
FAN SPEED
SELECT
HH
MM
TIME SET
SETBACK
NIGHT
ACL
OFF
E
ON
CLOCK
TIMER
SELECT
A/C
SENSOR
3
1
4
2
NIGHT SETBACK MODE
●
The night setback mode enables you to save energy.
1. Set the MODE selector to cool, dry or heat.
2. Press the NIGHT SETBACK button.
3. The mark appears on the display. Press the NIGHT
SETBACK button again to release the night setback function.
What does the Night Setback mode mean?
In this mode, the air conditioner will cool or heat the room to the
set temperature, and then the thermostat will make the unit pause.
After about 30 minutes, the air conditioner will automatically reset
the set temperature as follows (also refer to graphs).
OPERATING MODE
SET TEMPERATURE CHANGE
Heating
Lowered by 2 °C
Cooling and Dehumidifying
Raised by 1 °C
When the room temperature reaches the new set value, the
thermostat will cause the unit to pause. After about 30 minutes the
temperature will be raised by 1 °C in cooling, or lowered by 2 °C
in heating. This enables you to save energy without sacrificing
your comfort.
After timer setting, press PROGRAM button in order to check the
ON/OFF setting time.
NOTE