background image

SAFETY : Read this First !  

• 

Do not connect the appliance if there are obvious signs of transportation 

damage. 

• 

Read this user manual thoroughly before attempting to use this appliance. 

• 

Installation and repair should be attempted only by qualified technical personnel. 

• 

It is dangerous to modify any part of this appliance. 

• 

The manufacturer declines all responsibility in case of failure to adopt proper 

safety measures. 

• 

Ensure the location in which this appliance is installed has good, permanent 

ventilation. 

• 

The distance between the bench top to the lower part of the hood must not be at 

less than 65 cm or higher than 75 cm. 

• 

Use an electrical connector with earth that is correct for your location. 

• 

Check that the voltage in your area is correct  before plugging in. 

• 

The electrical connection of this appliance must be connected to earth. 

Green & yellow

 

 

= EARTH 

Blue = 

NEUTRAL 

Brown 

  = 

LIVE

 

• 

Multiple plugs and extension cables must not be used. Overload is dangerous 

and may cause a fire. 

• 

Ensure that the power supply chord is free from any heat source or sharp 

objects. 

• 

The appliance should be switched off and the electrical supply disconnected 

before any cleaning or maintenance work can be carried out.. 

• 

 This

 

appliance

 

is

 

not

 

intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety. 

      Children should be supervised to ensure that they do not play with the appliance. 

Cleaning & Maintenance 

(continued)

 

Activated charcoal filter 

To install the charcoal filter, the motor anchorage is made to coincide with the 

anchor points of the activated charcoal filter, inserting and locking into place.  

The carbon filter lasts from three to six months depending on the particular 

conditions of use. 

 

The activated carbon filter can neither be exhausted, it must be changed. 

Once it is exhausted, it must be changed.

 

 

Changing Bulbs 

Remove the filter support to access the bulbs.

 

 

Take care to disconnect the mains beforehand and that the bulbs to be 

replaces are not hot. 

The maximum bulbs power is 40W. 

13 

Summary of Contents for SL10160I-3

Page 1: ...安 装 和 使用指示 For original parts reliable service TECHNIKA 1800 333 244 TELESCOPIC HOOD INSTRUCTIONS FOR INSTALLATION AND USE USER S MANUAL SL10160I 3 SRECO160I 2 ...

Page 2: ...st 4 5 Vent System Requirements 5 Ducted vs Re circulating 6 7 Description of Parts 8 Instruction for Use 9 Technical Information 10 Installation 11 Cleaning Maintenance 12 13 Troubleshooting 14 Schematic Diagram 15 2 Schematic Diagram 15 For Service Contact Technika 1800 333 244 ...

Page 3: ...t be installed Strong cooking smell Aluminum grease filter saturated Wash the aluminium grease filters Oil dripping onto stove Aluminum grease filter saturated Wash the aluminium grease filters Whirring sound Foreign object in contact with fan blade Contact technician From the Manufacturer This appliance and it s packaging are produced by processes that minimize waste and respect the environment P...

Page 4: ... power supply chord is free from any heat source or sharp objects The appliance should be switched off and the electrical supply disconnected before any cleaning or maintenance work can be carried out This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision o...

Page 5: ...c cleaners such as lime scale remover etc as these could damage the surface and can result in the development of rust and corrosion Do not use scrapers with metallic surfaces such as knives scissors etc 12 SAFETY Read this First Continued If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard There is a fire...

Page 6: ...cated at a minimum height of 60cm above the hob for electric cookers and 65cm for gas cookers If the instructions of a gas cooker indicate a greater distance these must be observed When the extractor is working at the same time as other non electrical cooking equipment the outlet air pressure must not exceed 4 Pa To achieve optimum performance the length of the outlet hose should not exceed 4 mete...

Page 7: ...REC0160I 2 Ducted vs Re circulating Continued B RE CIRCULATING MODE Depending on model Fumes are filtered for grease and odors through the aluminum grease filters and the charcoal filters respectively and re introduced into the kitchen environment In re circulating mode both the aluminum grease filters and the charcoal filters must be installed 7 ...

Page 8: ...rol the functions of the extractor To achieve better extraction we recommend switching on the extractor a few minutes before starting to cook 3 5 minutes so that the air flow is continuous and stable when extracting fumes Likewise keep the extractor switched on for a few minutes when cooking is complete to allow all fumes and odors to be expelled 9 Speed Low High Automatic Light ON Off Off ...