Snooze function 

1. 

Press “

SNOOZE/LIGHT

” button and the white backlights activates for 10 seconds. 

2. 

When alarm sounds, press the “

SNOOZE/LIGHT

” button to trigger snooze for 10 minutes. The alarm icon 

flashes when the snooze feature is active. 

 

Note: 

  To  stop  alarm  for  one  day,  press  any  button  but 

SNOOZE/LIGHT

” button,  while in snooze mode. The 

alarm icon will stop flashing. 

 

Backlight function 

 

With adapter, the display will always have backlight on.  

 

Without adapter, 

press the “

SNOOZE/LIGHT

” button to turn on backlight for 10 seconds. 

 

MAX/MIN values:   

 

In normal display mode, press the 

“MIN/MAX”

 button to display maximum temperature/humidity. Press 

the 

“MIN/MAX”

 button once more to display minimum temperature/humidity. 

 

Press and hold the 

“MIN/MAX”

 button for 3 seconds in the corresponding interface to clear max or min 

temperature/humidity memory. 

 

After 5 seconds the display will return back to the normal display mode.  

 

The MIN/MAX values will also be automatically cleared at every midnight (0:00). 

 

Barometer and bar and data of history for the past 12 hour of air pressure 

 

 

Air pressure history can be displayed in hPa , for the past 12 hours   

 

The bar graph indicates the air pressure history trend over the last 12 

hours in 6 intervals: 0h, -1h, -2h, -3h, -6h, and -

12h. The “0h” represents 

the current full hour air pressure recording. The columns represent the 
“hPa” (0, ±2, ±4, ±6) at a specific time. The “0” in the middle of this scale 

is equal to the current pressure and each change (±2, ±4, ±6 ) represents 
how high or low in “hPa“ the past pressure was compared to the current 

pressure.  

 

For accurate barometric pressure trends, the weather station should 

operate at the same altitude for recordings (i.e. it should not be moved from the ground to the second floor 

of the house). When the unit is moved to a new location, discard readings for the next 12 hours. 

 

Weather forecast 

5 Weather forecast symbols can be displayed: sunny, partly sunny, cloudy, rainy, stormy

 

 

 

Note: 

 

The weather forecast is determined by temperature, humidity and air pressure. The forecast symbol may 

not match with the current weather. 

 

 

Changing temperature unit 

Summary of Contents for WS 6449

Page 1: ...e force or shock Do not expose the unit to extreme temperatures direct sunlight dust or humidity Do not immerse in water Avoid contact with any corrosive materials Do not dispose this unit in a fire as it may explode Do not open the inner back case or tamper with any components of this unit Batteries safety warnings Use only alkaline batteries not rechargeable batteries Install batteries correctly...

Page 2: ...eneral household waste when it reaches the end of its useful life Take your unit to your local waste collection point or recycling centre This applies to all countries of the European Union and to other European countries with a separate waste collection system Features Calendar Date month 2000 2099 Default Year 2016 Indoor Temperature and Humidity Outdoor Temperature and Humidity 12 24 h time for...

Page 3: ...or sensor Then press the TX button on the sensor to send signal If it still does not receive the outdoor temperature remove the batteries from the transmitter and go back to step 1 of the set up Sensor Reception Press and hold the CH button for 3 seconds while viewing an empty channel to search for the sensor The strength signal icon will flash until the sensor signal is received or for 3 minutes ...

Page 4: ...and hold the SET button for 3 seconds in normal display mode to enter time setting mode 2 12Hr or 24Hr will flash Press the or button to select between the 12 hour or 24 hour time format Press the SET button to confirm and continue 3 The time zone will flash on the display Press the or button to set the desired time zone setting range is 0 12 0 12 Press the SET button to confirm and continue 4 The...

Page 5: ... long as the alarm is activated and the alarm icon will no longer be displayed as soon as the alarm is deactivated 3 Press the ALARM button once again to confirm and return to the normal display mode ALM will no longer be shown on the display Alarm setting 1 Press and hold the ALARM button for 3 seconds in normal display mode to enter alarm setting mode 2 The alarm hour will flash Press the or but...

Page 6: ... be automatically cleared at every midnight 0 00 Barometer and bar and data of history for the past 12 hour of air pressure Air pressure history can be displayed in hPa for the past 12 hours The bar graph indicates the air pressure history trend over the last 12 hours in 6 intervals 0h 1h 2h 3h 6h and 12h The 0h represents the current full hour air pressure recording The columns represent the hPa ...

Page 7: ...F Resolution 0 1 degree Celsius When above 50 C 122 F the LCD will display HI When below 9 9 C 14 F the LCD will display LO Indoor Humidity Operating humidity range 20 RH to 95 Accuracy 5 RH Resolution 1 RH Outdoor temperature Operating temperature range 40 C to 60 C 40 F to 140 F Accuracy 1 degrees Celsius from 0 C to 50 C 32 F to122 F Accuracy 1 5 degrees Celsius 40 C to 0 C 40 F to 32 F and 50 ...

Reviews: