6.5. THERE IS NO RESISTANCE
The machine will not produce resistance if:
•
the digital plan board does not receive a speed signal;
•
the brake board does not generate current;
•
the brake is defective.
Does the brake board supply
current to the brake winding?
THERE IS NO
RESISTANCE
Are the Watt and RPM v alues
shown on the display dif f erent
f rom zero?
NO
YES
1
Carry out the "RPM v alue
is incorrect"
troubleshooting procedure
Replace the brake board
YES
Does the brake winding receiv e
current f rom the brake board?
NO
Replace the brake winding
YES
Replace cable CB-51
NO
2
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Disconnect the brake winding and measure the current output by the brake board with a load
of at least 5 Ohm and 80 Watts. The value should be different from 0 A.
(2)
As for step (1) but with everything reconnected, and across the brake winding.