BIKE FORMA: Service & Maintenance Manual - rev. 1.0
Page 9.13
Error
Code
Description
1
OVERHEATING:
this condition occurs when the temperature measured
by the sensor on the circuit board exceeds 90°C.
2
OVERCURRENT:
this condition occurs when the current going to the
solenoid measured by the board exceed the max value.
4
UNDERVOLTAGE:
this condition occurs when the +12 Vdc voltage
drops below 9.7 Vdc.
8
OVERVOLTAGE:
this condition occurs when the +12 Vdc voltage goes
above 13.7 Vdc.
32
EPROM:
SW error on the brake board.
128
MACHINE NOT CALIBRATED:
this error condition occurs when the
calibration parameter stored in the brake board is incorrect.
Use the
+
speed key to advance to the next error, otherwise the message with the details of the
current error will continue to reappear.
9.2.5. S
TANDARD SETTINGS
This function simultaneously resets the User menu and the brake board parameters to their default
values. To access this menu, when the LED display shows:
STANDARD SETTINGS ?
press
ENTER
, the following message appears:
CONFIRM ?
Press
ENTER
again to reset all parameters to their default values, or return to the upper menu level
by pressing
CLEAR
for a few seconds.
This function does not alter the language setting.
9.2.6. L
OW KIT MENU
This function directly accesses the firmware of the brake board. To access this menu, when the LED
display shows:
LOW KIT MENU
press
ENTER
. This function is structured as follows:
LOW KIT MENU
Low Kit Version
Low Kit fault code
Summary of Contents for Bike Forma
Page 1: ...SERVICE MAINTENANCE MANUAL REV 1 0...
Page 2: ......
Page 4: ......
Page 8: ...BIKE FORMA Service Maintenance Manual rev 1 0 Page iv Page intentionally left blank...
Page 25: ...BIKE FORMA Service Maintenance Manual rev 1 0 Page 3 9 Page intentionally left blank...
Page 26: ......
Page 28: ...BIKE FORMA Service Maintenance Manual rev 1 0 Page 4 2 Page intentionally left blank...
Page 68: ...BIKE FORMA Service Maintenance Manual rev 1 0 Page 7 20 Page intentionally left blank...
Page 93: ......