RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 6.38
6.16.
THERE IS NO HEART RATE SIGNAL
6.16.1.
SALUTRON
TELEMETRIC RECEIVER
The machine displays this error if:
1.
electromagnetic noise saturate the HR receiver which does not display any value due to a
specific SW filter which cut every signal, greater than 220 bpm;
2.
the receiver is not working properly;
3.
the receiver is not supplied by the display board.
THERE IS NO HR
SIGNAL
Is the v oltage at the input to the
receiv er, correct?
Is the v oltage at the output of
the display board, correct?
Replace the receiv er
Check the wiring and
earth connection and/or
replace the CU206 cable
2
3
YES
NO
YES
Replace display board
NO
Carry out the
troubleshooting procedure
"THE TELEMETRIC
SIGNAL IS INCORRECT"
1
4
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
Summary of Contents for EXCITE Run 500
Page 1: ...D446 D448 D449 SERVICE MAINTENANCE MANUAL REV 1 3...
Page 2: ......
Page 4: ......
Page 32: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 2 20 Page intentionally left blank...
Page 52: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 3 20 Page intentionally left blank...
Page 59: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 7 Page intentionally left blank...
Page 60: ......
Page 127: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 7 19 Continued on following page...
Page 148: ......
Page 217: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 9 63 Page intentionally left blank...
Page 218: ......
Page 229: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 11 7 Page intentionally left blank...
Page 230: ......
Page 233: ......