RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 6.40
6.16.2.
H
AND SENSOR
The machine displays this error if the HS/HR receiver is not working, or if it is not supplied by the
display board.
For an easier and quicker diagnosis of the problem, we recommend to use the
functions of Test Box Excite.
THERE IS NO HR
SIGNAL
Are the sensors correctly
connected to the HS/HR
receiv er?
Is the v oltage at the output of
the display board correct ?
Reinstate the connection
Replace cable CU206
Replace the display board
2
4
YES
NO
YES
NO
Is the v oltage at the input to the
HS/HR receiv er correct?
Replace the HS/HR
receiv er
3
YES
NO
Check the wiring and earth
connection of the machine
1
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
Summary of Contents for EXCITE Run 500
Page 1: ...D446 D448 D449 SERVICE MAINTENANCE MANUAL REV 1 3...
Page 2: ......
Page 4: ......
Page 32: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 2 20 Page intentionally left blank...
Page 52: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 3 20 Page intentionally left blank...
Page 59: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 7 Page intentionally left blank...
Page 60: ......
Page 127: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 7 19 Continued on following page...
Page 148: ......
Page 217: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 9 63 Page intentionally left blank...
Page 218: ......
Page 229: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 11 7 Page intentionally left blank...
Page 230: ......
Page 233: ......