RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 6.42
6.17.
THE TELEMETRIC HEART RATE SIGNAL IS INCORRECT
The machine displays this error if the receiver is disturbed by sources of electromagnetic noise.
THE TELEMETRIC
HR SIGNAL IS
INCORRECT
Are the machines correctly
spaced by the required minimum
distance?
Is the receiv er correctly
positioned and are the
connecting cables properly
routed?
Are there sources of
electromagnetic noise near the
receiv er?
Reposition the machines
so they are adequately
spaced
Correct the position of the
receiv er and the routing of
the cables
Mov e the machine away
f rom the noise source or
attenuate the power of the
noise
NO
YES
NO
YES
NO
YES
4
A
Check the earth connection
of the machine
1
3
2
Continued on the following page
Summary of Contents for EXCITE Run 500
Page 1: ...D446 D448 D449 SERVICE MAINTENANCE MANUAL REV 1 3...
Page 2: ......
Page 4: ......
Page 32: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 2 20 Page intentionally left blank...
Page 52: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 3 20 Page intentionally left blank...
Page 59: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 7 Page intentionally left blank...
Page 60: ......
Page 127: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 7 19 Continued on following page...
Page 148: ......
Page 217: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 9 63 Page intentionally left blank...
Page 218: ......
Page 229: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 11 7 Page intentionally left blank...
Page 230: ......
Page 233: ......