RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 7.21
7.13.
FAN AND LIMIT SWITCH DISASSEMBLY
Figure7.13-1
Carry out the procedure described in
paragraph: 7.12. “Motor guard disassembly”.
There are now accessible:
•
The motor fan
(X)
,
•
The limit switch
(Y)
.
Figure7.13-2
Motor fan disassembly
(X)
:
1.
Back off the 3 screws
(a)
using a medium
Phillips screwdriver.
2.
Remove the fan.
Figure7.13-3
Limit switch disassembly
(Y)
:
1.
Loosen the 2 bolts
(a)
with a 8mm hexagonal
wrench and remove the limit switch from the
guard.
To reassemble the fan and the limit switch, carry
out the above steps in reverse order.
After the limit switch reassembly, check
its position, as described at paragraph:
8.4. “Limit switch position”.