JOG EXCITE: Service & Maintenance Manual - rev. 1.1
Page 11.1
11.
APPENDIX
11.1.
UPDATING THE SW
The machine SW is updated by writing to the contents of the FLASH EPROM on the ARM board
from an external PC connected to the CSAFE port on the machine, situated on the lower part of the
display panel.
The PC can only update the FLASH EPROM during machine power up, before the self-
test sequence begins.
After the Display SW update it is necessary to restore all the parameters to the default
values following the detailed instructions provided in paragraph 9.1.15. “Resetting
parameters to default values”.
After the lower electronic SW update it is necessary to restore all the parameters to the
default values following the detailed instructions provided in paragraph 9.2.1.3 “Default
setting”.