JOG NOW : Service & maintenance manual - rev. 6.2
Page 6.30
6.14.
THERE IS NO HEART RATE SIGNAL
6.14.1.
HR/HS
RECEIVER
(H
AND
S
ENSOR
)
700 models
HUMAN BODY “CONTINUITY”: it’s well known that for somebody it’s very difficult,
nearly impossible, to measure their HR using the hand sensors. This due to a lot of
possible causes which could fake the “quality” of the contact between the human skin
and the HS plates, as: hands only just washed or particularly dry, acidity of the skin
and/or a particular body fat mass index. For these people it’s suggested to wear the chest
belt transmitter.
HS CORRECT USE: Grasp both the upper and lower plate avoiding clenching them too
hardly. Avoid washing the hands using soaps that can dry the skin too much.
The machine displays this error if the
HR/HS Receiver
does not work or is not powered by the
CPU/ARM Board.
Continued on following page...