JOG NOW : Service & maintenance manual - rev. 6.2
Page 6.42
(3)
Check if the receiver has been correctly mounted on the machine, as detail at paragraph: 7.6.
“Disassembling the cardio receiver”.
(4)
To check for electromagnetic noise near the machine, use Test Box Excite as detailed here
below. You can use one of the following cables
ELT-16
(0WC00518AB),
CBQ-28
(0WC00390AC) or
TRM-28
(0WC00336AC) as connection cable.
TEST BOX
EXCITE
RECEIVER
LED
Connecting cable
The circuit lights the LED for each heart beat and/or disturbance received: in this way it is
possible to determine whether there is any interference, and identify its sources.
Do not keep the Test Box Excite too close to the display, to avoid the electric
interference.