RECLINE EXCITE: Service & Maintenance Manual - rev. 2.4
-
commands determining the resistance that is required of the brake;
-
brake error messages;
-
the commands for modifying the circuit board configuration parameters;
-
the commands for viewing the errors logged by the circuit board.
•
Section which generates the current for the brake winding: varying the current produces a
proportional variation in the resistance of the brake. The excitation current supplied to the brake
is a function of the effort level selected on the display and the RPM value measured by the
speed sensor (angular velocity of the brake disk and is determined by the values stored in the
braking table.
The board includes the following indicator LEDs:
LED name
Color
Description
LED1 green
if ON the board is supplying the brake winding.
if BLINKING the brake board is in an error condition.
LED2 yellow
if ON there is the +5 Vdc power supply from the
circuit board.
3.1.8. B
RAKE
This is an eddy current brake, consisting of a flywheel mass and a flat copper disk that rotates in the
air gap of a winding. Variations in the winding current produce a change in the resulting field,
which consequently varies the eddy currents induced within the copper disk and hence its resistance
to movement.
The winding has a resistance of approximately 4.8 Ohm.
3.1.9. S
PEED SENSOR
This consists of a magnetic induction sensor which detects the heads of the brake disk fixing
screws.
3.1.10. P
OWER ENTRY MODULE
Only for 500i, 700i and 700iE versions.
his is a block consisting of:
T
•
power inlet socket;
•
power outlet socket;
fuse-holder for protecting line voltage and neutral with two 3.15A fast-blow fuses.
•
Situated on the side of the rear platform, the power entry module has a maximum current rating of
10A. This determines the maximum number of machines that can be connected together. Therefore,
do not connect more than 30 Bike Excite machines with a 220 VAC mains supply, or 15 machines
ith a 110 VAC mains supply.
w
WARNING: If other types of machines are connected together, the maximum number is
determined by their current draw.
Page 3.9
Summary of Contents for Recline 500
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 4...
Page 2: ......
Page 4: ......
Page 10: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page vi Page intentionally left blank...
Page 46: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page 3 14 Page intentionally left blank...
Page 58: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page 4 12 Page intentionally left blank...
Page 94: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page 6 34 Page intentionally left blank...
Page 134: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page 7 40 Page intentionally left blank...
Page 140: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page 8 6 Page intentionally left blank...
Page 172: ...RECLINE EXCITE Service Maintenance Manual rev 2 4 Page 9 32 Page intentionally left blank...
Page 181: ......