RUN 600 XTPRO: Service & Maintenance Manual - rev. 1.3
Page 2.10
2.7. WIRING DIAGRAM FOR THE 110 USA MODEL
The 110 VAC mains supply is handled by an autotransformer connected to the output of the
automatic circuit breaker, which receives the 110 VAC input and generates the 220 VAC output.
From this point onward the machine wiring diagram is the same as for the 220 version:
The differences compared to the 220 USA model are:
•
the automatic circuit breaker is 20 A - class D instead of 10 A - class C;
•
autotransformer 110 - 220;
•
mains lead with different cable section and plug;
•
16 A filter instead of a 20 A;
•
safety switch as in 220 USA model.