RUN 600 XTPRO: Service & Maintenance Manual - rev. 1.3
Page 6.6
6.2. THE INVERTER IS OFF
This condition is related to emergency button or relay.
THE INVERTER IS OFF
Is the emergency button pressed?
Is the v oltage at the output of the CPU
board correct?
Replace the CPU board
Correct operation
YES
NO
NO
1
Is the v oltage at the CN11 patch
connector correct?
Replace emergency
button
NO
YES
3
Is the v oltage at the emergency
button correct?
Replace RN-13S cable
YES
YES
NO
2
A
Continued on the following page.