RUN 600 XTPRO: Service & Maintenance Manual - rev. 1.3
Page 6.13
6.4.3. T
HE INVERTER DISPLAY SHOWS
E08, E10
OR
E11
These inverter error messages are related to HW and SW problems with the inverter.
Does the error occur
frequently?
YES
Replace the inverter
Probable interference. The
machine is OK
NO
Does the machine resume
correct operation after being
turned off for 1 minute?
YES
Re-program the inverter
NO
1
Does the machine resume
correct operation after being
turned off for 10 minutes?
Programming correct. The
machine is OK
Replace the inverter
NO
YES
E10
E08
E11
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Determine the frequency of the errors by counting the number of occurrences in the inverter
error memory, and by running targeted checks. An error is considered frequent if it occurs 2 or
3 times a day.
WARNING: incorrect programming of the inverter can cause serious damage to the
machine or malfunctioning that is potentially hazardous to the user. Therefore, attempt
this operation only if certain of being able to carry out the procedure with the proper
parameters setting.
Summary of Contents for RUN 600 XTPRO
Page 1: ...SERVICE MAINTENANCE MANUAL REV 1 3...
Page 2: ......
Page 4: ......
Page 24: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 2 14 Page intentionally left blank...
Page 36: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 3 12 Page intentionally left blank...
Page 38: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 4 2 Page intentionally left blank...
Page 82: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 6 42 Page intentionally left blank...
Page 126: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 8 10 Page intentionally left blank...
Page 156: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 11 14 Page intentionally left blank...
Page 157: ......