RUN 600 XTPRO: Service & Maintenance Manual - rev. 1.3
Page 6.26
6.7. THE DISPLAYED SPEED IS INCORRECT
The machine displays this error if:
•
the calibration is incorrect;
•
there are HW problems with the CPU board – driver board – inverter and motor group.
THE DISPLAYED SPEED IS
INCORRECT
Is the relationship between the
displayed speed and the inverter
frequency correct?
Is the inverter control voltage
correct?
YES
NO
YES
Replace the inverter
3
4
NO
The machine is operating
correctly
A
Is the configuration of the
measurement system correct?
Configure the machine
1
YES
NO
Check the inverter
parameters setting and
regulate the speed
2
Continued on the following page.