RUN 600 XTPRO: Service & Maintenance Manual - rev. 1.3
Page 6.30
A
Is fuse F1 of the elevation board
OK?
NO
Replace the fuse
YES
Does the elevation board receive
the mains electricity supply?
NO
Check and/or replace the
cable connecting the
elevation board to the
filter
YES
Does the voltage at output by the
transformer-rectifier reach the
elevation board?
NO
Replace the elevation
board
YES
Is the voltage at the transformer
output correct?
Replace the transformer
Replace the rectifier
bridge
YES
NO
5
6
4
Aer the 2 limit switches OK?
NO
Replace the limit switches
YES
Continued on the following page.