RUN 600 XTPRO: Service & Maintenance Manual - rev. 1.3
Page 6.36
6.10. THE DISPLAYED ELEVATION IS INCORRECT
The machine displays this error if there is a mismatch between the photocell model and the SW of
the elevation board or there is a bad photocell reading due to incorrect calibration, breakage or
disturbances produced by the motor brushes as a result of excessively high currents.
THE DISPLAYED
ELEVATION IS INCORRECT
Is the position of the limit switch
correct?
Is the elevation motor current
correct?
YES
NO
YES
Lubricate the elevation
bars
2
NO
Adjust limit switch
position
Is the photocell clean?
Clean the photocell
YES
Replace the photocell and
cable connecting the
elevation board and the
photocell
NO
Are the elevation bars lubricated?
NO
Replace the elevation
motor
YES
Is the SW of the elevation board
matching the photocell model?
NO
Install the proper version
YES
1
Summary of Contents for RUN 600 XTPRO
Page 1: ...SERVICE MAINTENANCE MANUAL REV 1 3...
Page 2: ......
Page 4: ......
Page 24: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 2 14 Page intentionally left blank...
Page 36: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 3 12 Page intentionally left blank...
Page 38: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 4 2 Page intentionally left blank...
Page 82: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 6 42 Page intentionally left blank...
Page 126: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 8 10 Page intentionally left blank...
Page 156: ...RUN 600 XTPRO Service Maintenance Manual rev 1 3 Page 11 14 Page intentionally left blank...
Page 157: ......